A web user interface to manage your WireGuard setup.
- Friendly UI
- Authentication
- Manage extra client information (name, email, etc)
- Retrieve client config using QR code / file / email
⚠️ The default username and password areadmin
. Please change it to secure your setup.
Download the binary file from the release page and run it directly on the host machine
./wireguard-ui
You can take a look at this example of docker-compose.yml. Please adjust volume mount points to work with your setup. Then run it like below:
docker-compose up
Note:
- There is a Status page that needs docker to be able to access the network of the host in order to read the
wireguard interface stats. See the
cap_add
andnetwork_mode
options on the docker-compose.yaml - Similarly, the
WGUI_MANAGE_START
andWGUI_MANAGE_RESTART
settings need the same access, in order to restart the wireguard interface. - Because the
network_mode
is set tohost
, we don't need to specify the exposed ports. The app will listen on port5000
by default.
Variable | Description | Default |
---|---|---|
BASE_PATH |
Set this variable if you run wireguard-ui under a subpath of your reverse proxy virtual host (e.g. /wireguard)) | N/A |
SESSION_SECRET |
The secret key used to encrypt the session cookies. Set this to a random value | N/A |
WGUI_USERNAME |
The username for the login page. Used for db initialization only | admin |
WGUI_PASSWORD |
The password for the user on the login page. Will be hashed automatically. Used for db initialization only | admin |
WGUI_PASSWORD_HASH |
The password hash for the user on the login page. (alternative to WGUI_PASSWORD ). Used for db initialization only |
N/A |
WGUI_FAVICON_FILE_PATH |
The file path used as website favicon | Embedded WireGuard logo |
WGUI_ENDPOINT_ADDRESS |
The default endpoint address used in global settings | Resolved to your public ip address |
WGUI_DNS |
The default DNS servers (comma-separated-list) used in the global settings | 1.1.1.1 |
WGUI_MTU |
The default MTU used in global settings | 1450 |
WGUI_PERSISTENT_KEEPALIVE |
The default persistent keepalive for WireGuard in global settings | 15 |
WGUI_FORWARD_MARK |
The default WireGuard forward mark | 0xca6c |
WGUI_CONFIG_FILE_PATH |
The default WireGuard config file path used in global settings | /etc/wireguard/wg0.conf |
WG_CONF_TEMPLATE |
The custom wg.conf config file template. Please refer to our default template |
N/A |
EMAIL_FROM_ADDRESS |
The sender email address | N/A |
EMAIL_FROM_NAME |
The sender name | WireGuard UI |
SENDGRID_API_KEY |
The SendGrid api key | N/A |
SMTP_HOSTNAME |
The SMTP IP address or hostname | 127.0.0.1 |
SMTP_PORT |
The SMTP port | 25 |
SMTP_USERNAME |
The SMTP username | N/A |
SMTP_PASSWORD |
The SMTP user password | N/A |
SMTP_AUTH_TYPE |
The SMTP authentication type. Possible values: PLAIN , LOGIN , NONE |
NONE |
SMTP_ENCRYPTION |
the encryption method. Possible values: NONE , SSL , SSLTLS , TLS , STARTTLS |
STARTTLS |
These environment variables are used to control the default server settings used when initializing the database.
Variable | Description | Default |
---|---|---|
WGUI_SERVER_INTERFACE_ADDRESSES |
The default interface addresses (comma-separated-list) for the WireGuard server configuration | 10.252.1.0/24 |
WGUI_SERVER_LISTEN_PORT |
The default server listen port | 51820 |
WGUI_SERVER_POST_UP_SCRIPT |
The default server post-up script | N/A |
WGUI_SERVER_POST_DOWN_SCRIPT |
The default server post-down script | N/A |
These environment variables are used to set the defaults used in New Client
dialog.
Variable | Description | Default |
---|---|---|
WGUI_DEFAULT_CLIENT_ALLOWED_IPS |
Comma-separated-list of CIDRs for the Allowed IPs field. (default ) |
0.0.0.0/0 |
WGUI_DEFAULT_CLIENT_EXTRA_ALLOWED_IPS |
Comma-separated-list of CIDRs for the Extra Allowed IPs field. (default empty) |
N/A |
WGUI_DEFAULT_CLIENT_USE_SERVER_DNS |
Boolean value [0 , f , F , false , False , FALSE , 1 , t , T , true , True , TRUE ] |
true |
WGUI_DEFAULT_CLIENT_ENABLE_AFTER_CREATION |
Boolean value [0 , f , F , false , False , FALSE , 1 , t , T , true , True , TRUE ] |
true |
These environment variables only apply to the docker container.
Variable | Description | Default |
---|---|---|
WGUI_MANAGE_START |
Start/stop WireGuard when the container is started/stopped | false |
WGUI_MANAGE_RESTART |
Auto restart WireGuard when we Apply Config changes in the UI | false |
WireGuard-UI only takes care of configuration generation. You can use systemd to watch for the changes and restart the service. Following is an example:
Create /etc/systemd/system/wgui.service
cd /etc/systemd/system/
cat << EOF > wgui.service
[Unit]
Description=Restart WireGuard
After=network.target
[Service]
Type=oneshot
ExecStart=/usr/bin/systemctl restart wg-quick@wg0.service
[Install]
RequiredBy=wgui.path
EOF
Create /etc/systemd/system/wgui.path
cd /etc/systemd/system/
cat << EOF > wgui.path
[Unit]
Description=Watch /etc/wireguard/wg0.conf for changes
[Path]
PathModified=/etc/wireguard/wg0.conf
[Install]
WantedBy=multi-user.target
EOF
Apply it
systemctl enable wgui.{path,service}
systemctl start wgui.{path,service}
Create /usr/local/bin/wgui
file and make it executable
cd /usr/local/bin/
cat << EOF > wgui
#!/bin/sh
wg-quick down wg0
wg-quick up wg0
EOF
chmod +x wgui
Create /etc/init.d/wgui
file and make it executable
cd /etc/init.d/
cat << EOF > wgui
#!/sbin/openrc-run
command=/sbin/inotifyd
command_args="/usr/local/bin/wgui /etc/wireguard/wg0.conf:w"
pidfile=/run/${RC_SVCNAME}.pid
command_background=yes
EOF
chmod +x wgui
Apply it
rc-service wgui start
rc-update add wgui default
Set WGUI_MANAGE_RESTART=true
to manage Wireguard interface restarts.
Using WGUI_MANAGE_START=true
can also replace the function of wg-quick@wg0
service, to start Wireguard at boot, by
running the container with restart: unless-stopped
. These settings can also pick up changes to Wireguard Config File
Path, after restarting the container. Please make sure you have --cap-add=NET_ADMIN
in your container config to make
this
feature work.
Go to the project root directory and run the following command:
docker build -t wireguard-ui .
Prepare the assets directory
./prepare_assets.sh
Then you can embed resources by generating Go source code
rice embed-go
go build -o wireguard-ui
Or, append resources to executable as zip file
go build -o wireguard-ui
rice append --exec wireguard-ui
MIT. See LICENSE.
If you like the project and want to support it, you can buy me a coffee ☕