Prometheus exporter for SolarEdge inverters

Primary LanguageGoMIT LicenseMIT

SolarEdge Prometheus Exporter

Having just installed a SolarEdge inverter and not happy with the 15 minute delay and low resolution of the monitoring data provided by the monitoring service/api, I created this exporter to connects directly to SolarEdge inverter over ModBus TCP to export (near) real time data to Prometheus.

Status

The code could use some clean up but I have had it running for a weeks scraping data from the inverter every 5 seconds without any issues.

Requirements

  • SolarEdge Inverter that supports SunSpec protocol (Tested with SE5000 w. CPU version 3.2221.0)
  • ModBus TCP Enabled on the inverter
  • Local network connection to the inverter (No ZigBee/GSM support)

Modbus TCP is a local network connection only and does not interfere or replace your connection to the SolarEdge monitoring service. As per the SolarEdge documentation, the two monitoring methods can be used in parallel without impacting each other.

More information on how to enable ModBus TCP can be found in the SolarEdge Documentation here

TODO

  • Implement consumption meter output.
    • This may already be working however my consumption meter is not installed yet so I cannot test

Quick Start

  1. Download the binary from the Releases section for your platform

  2. Configure the exporter using one of the two methods available.

    Replace the IP address in these samples with the address of your inverter

    • Environment Variables:
    	INVERTER_ADDRESS=192.168.1.189
    	EXPORTER_INTERVAL=5
    	INVERTER_PORT=502
    
    • config.yaml: Create a config file named config.yaml in the same location that you downloaded the executable with the following contents:
    SolarEdge:
      InverterAddress: "192.168.1.189"
      InverterPort: 502
    Exporter:
      # Update Interval in seconds
      Interval: 5	
  3. Add the target to your prometheus server with port 2112

Metrics

Metric Type Description/Help
SunSpec_DID Guage 101 = single phase 102 = split phase1 103 = three phase
SunSpec_Length Guage Registers 50 = Length of model block
AC_Current Guage Amps AC Total Current value
AC_CurrentA Guage Amps AC Phase A Current value
AC_CurrentB Guage Amps AC Phase B Current value
AC_CurrentC Guage Amps AC Phase C Current value
AC_Current_SF Guage AC Current scale factor
AC_VoltageAB Guage Volts AC Voltage Phase AB value
AC_VoltageBC Guage Volts AC Voltage Phase BC value
AC_VoltageCA Guage Volts AC Voltage Phase CA value
AC_VoltageAN Guage Volts AC Voltage Phase A to N value
AC_VoltageBN Guage Volts AC Voltage Phase B to N value
AC_VoltageCN Guage Volts AC Voltage Phase C to N value
AC_Voltage_SF Guage AC Voltage scale factor
AC_Power Guage Watts AC Power value
AC_Power_SF Guage AC Power scale factor
AC_Frequency Guage Hertz AC Frequency value
AC_Frequency_SF Guage Scale factor
AC_VA Guage VA Apparent Power
AC_VA_SF Guage Scale factor
AC_VAR Guage VAR Reactive Power
AC_VAR_SF Guage Scale factor
AC_PF Guage % Power Factor
AC_PF_SF Guage Scale factor
AC_Energy_WH Guage WattHours AC Lifetime Energy production
AC_Energy_WH_SF Guage Scale factor
DC_Current Guage Amps DC Current value
DC_Current_SF Guage Scale factor
DC_Voltage Guage Volts DC Voltage value
DC_Voltage_SF Guage Scale factor
DC_Power Guage Watts DC Power value
DC_Power_SF Guage Scale factor
Temp_Sink Guage Degrees C Heat Sink Temperature
Temp_SF Guage Scale factor
Status Guage Operating State
Status_Vendor Guage Vendor-defined operating state and error codes. For error description, meaning and troubleshooting, refer to the SolarEdge Installation Guide.