Use internal pull-up/down resistors
vincentwolsink opened this issue ยท 7 comments
Thanks for the great work. I am wondering, instead of using external pull-up/down resistors, wouldn't it be an option to use the esp internal ones?
I now see that the NPN sensor needs 5v to function. I am using a Cyble sensor which works fine with internal pull-up.
Would be nice if we could get a config with pull-up enabled.
Yes I can make a version with the internal resistor.
I will make it this week.
There hasn't been any activity on this issue recently, so we clean up some of the older and inactive issues. Please make sure to update to the latest version and check if that solves the issue. Let us know if that works for you by leaving a comment ๐ This issue has now been marked as stale and will be closed if no further activity occurs. Thanks!
Would still be nice to have this ๐
There hasn't been any activity on this issue recently, so we clean up some of the older and inactive issues. Please make sure to update to the latest version and check if that solves the issue. Let us know if that works for you by leaving a comment ๐ This issue has now been marked as stale and will be closed if no further activity occurs. Thanks!
Made a update to 2023.10.33 with this option on it.
Look at the special version.
Thanks, works! ๐