Different discharge port diameter but exactly same performance result
Wang-Zongwei opened this issue · 4 comments
Wang-Zongwei commented
I want to study with PDSim GUI the impact of different discharge port diameter on scroll compressor performance. But I found it seems no performance change (volumetric and isentropic efficiency) under different discharge port diameter input.
GUI version: PDSim 2.14 and CoolProp 6.5.0
All scroll input parameter keeps same as default setting value except discharge port diameter.
ibell commented
Are the coordinates of the port the same? You might want to put in the port
coordinates yourself
Wang-Zongwei commented
I did't input any coordinates for the discharge port (all x,y keeps blank). I will try with different coordinates input data to see if the performance result is different.
Wang-Zongwei commented
Wang-Zongwei commented
Thanks for your help. @ibell