Loggie operator is an optional supplementary and extensible component of Loggie. The current main functions are:

  • Automatically inject loggie sidecar and collect Pod container logs

Deploy and run

Local

  1. Deploy or run a Kubernetes cluster

  2. Generate certificate and MutatingWebhookConfiguration configuration

    The certificate is used by the webhook server that is automatically injected into the sidecar, please execute:

    LOCAL_IP=${ip}
    ./cert/generate_cert_local.sh --hostname ${LOCAL_IP}
    

    The LOCAL_IP should be set to the local IP address, and the network connectivity from the Kubernetes APIServer to the IP needs to be ensured.

    This step generates:

    • Certificates and keys, etc., are placed in the /tmp/cert directory by default
    • MutatingWebhookConfiguration configuration: you can use kubectl get mutatingwebhookconfiguration to view
  3. Run: make run

Usage

Automatically inject loggie sidecar

Pre-check:

  • Please ensure that in the config.yml configuration of the operator, sidecar.enabled is set to true, and the injected loggie image and system configuration meet the requirements. (deployed using helm chart, the configuration is in the values.yml file)
  • If the loggie DaemonSet is deployed in the Kubernetes cluster at the same time, in order to ensure that the LogConfig/clusterLogConfig created for injection into the sidecar does not affect the collection of the DaemonSet, please upgrade the Loggie DaemonSet version to v1.5+. This version of Loggie will ignore the sidecar.loggie .io/inject: "true" annotation for LogConfig/ClusterLogConfig.

Create Configuration:

  1. Create a LogConfig/ClusterLogConfig with sidecar.loggie.io/inject: "true" annotation.

    • The log collection configuration created here can be understood as the log collection configuration injected into the Pod Loggie sidecar.
    • This configuration is the same as DaemonSet, the only difference is that the annotation must be present, otherwise it will not be recognized by the Loggie Operator.
  2. Add sidecar.loggie.io/inject: "true" annotation to the pod template of the DaemonSet/StatefulSet used for collection.

    Please note:

    • The annotation needs to be added to the pod template of DaemonSet/StatefulSet, not the annotation of DaemonSet/StatefulSet itself. Only in this way, the created Pod will have the annotation.
    • After the DaemonSet/StatefulSet is newly created or the Pod is rebuilt, the Loggie Sidecar will be automatically injected

Example:

  1. Create a LogConfig with sidecar.loggie.io/inject: "true" annotations

eg:

cat << EOF | kubectl apply -f -
apiVersion: loggie.io/v1beta1
kind: LogConfig
metadata:
   annotations:
     sidecar.loggie.io/inject: "true"
   name: tomcat
   namespace: default
spec:
   pipeline:
     sink: |
       type: dev
       printEvents: true
       codec:
         pretty: true
     sources: |
       - type: file
         name: common
         paths:
           - /usr/local/tomcat/logs/**
   selector:
     labelSelector:
       app: tomcat
     type: pod
EOF
  1. Create a tomcat deployment with sidecar.loggie.io/inject: "true" annotations:

eg:

cat << EOF | kubectl apply -f -
apiVersion: apps/v1
kind: Deployment
metadata:
    name: tomcat
    namespace: default
spec:
    replicas: 1
    selector:
       matchLabels:
          app: tomcat
    template:
       metadata:
          annotations:
             sidecar.loggie.io/inject: "true"
          labels:
             app: tomcat
       spec:
          containers:
             - image: tomcat
               name: tomcat
EOF
  1. Verify:

    • Is Sidecar injection normal: kubectl get pod, tomcat contains two containers
    • Check whether there is a collection log, you can check it through kubectl logs -f ${pod-name} loggie

Other

Please note: