Plant monitoring and maintenance system for Arduino.
Development Blog: https://llefe001pc.tumblr.com/
Video Demonstration: https://vimeo.com/383220678
- Capacitive Sensors
- 580 default value (non-submerged)
- 310 lowest value (fully submerged)
- 350 best value (half submerged)
- When using all sensors at once, values change to: 335, 365, 580 (respectively)
- Values raise by approximately 60 in value when water pumps activate; 15 per active water pump. Possibly as power is drawn away, sensors become less accurate?
- Light Sensor
- 390 default value (regular position)
- 0 lowest value (completely dark)
- 530 medium value (10m distance)
- 670 max value (close proximity)
- Values may be less accurate due to power limitations.