Nextflow workflow for analysing Oxford Nanopore reads created by amplicon sequencing.

Introduction

This Nextflow workflow provides a simple way to analyse Oxford Nanopore reads generated from amplicons.

The workflow requires raw reads in FASTQ format and can be run in two modes:

  • Variant calling mode: Trigger this mode by passing a reference FASTA file. After initial filtering (based on read length and quality) and adapter trimming, minimap2 is used to align the reads to the reference. Variants are then called with Medaka. This mode allows for multiple amplicons per barcode (for details on how to map specific target amplicons to individual samples / barcodes, see below).
  • De-novo consensus mode: This mode is run when no reference file is passed. Like for the "variant calling mode", reads are first filtered and trimmed. Then, a consensus sequence is generated de novo from the reads of each sample. Reads are re-aligned against the draft consensus for polishing with Medaka. Please note that only one amplicon per barcode is supported in de-novo consensus mode.

Note: This workflow is not intended for marker gene sequencing of mixtures / communities of different organisms (e.g. 16S sequencing). In de-novo consensus mode it expects a single amplicon per barcode. When running in variant calling mode, multiple amplicons per barcode can be processed, but their sequences need to be sufficiently different from each other so that most reads only align to one of the provided references.

Compute requirements

Recommended requirements:

  • CPUs = 12
  • Memory = 32GB

Minimum requirements:

  • CPUs = 6
  • Memory = 16GB

Approximate run time: 0.5-5 minutes per sample (depending on number of reads, length of amplicons, and available compute).

ARM processor support: True

Install and run

These are instructions to install and run the workflow on command line. You can also access the workflow via the EPI2ME application.

The workflow uses Nextflow to manage compute and software resources, therefore Nextflow will need to be installed before attempting to run the workflow.

The workflow can currently be run using either Docker or Singularity to provide isolation of the required software. Both methods are automated out-of-the-box provided either Socker or Singularity is installed. This is controlled by the -profile parameter as exemplified below.

It is not required to clone or download the git repository in order to run the workflow. More information on running EPI2ME workflows can be found on our website.

The following command can be used to obtain the workflow. This will pull the repository in to the assets folder of Nextflow and provide a list of all parameters available for the workflow as well as an example command:

nextflow run epi2me-labs/wf-amplicon –-help

A demo dataset is provided for testing of the workflow. It can be downloaded using:

wget https://ont-exd-int-s3-euwst1-epi2me-labs.s3.amazonaws.com/wf-amplicon/wf-amplicon-demo.tar.gz
tar -xzvf wf-amplicon-demo.tar.gz

The workflow can be run with the demo data using:

nextflow run epi2me-labs/wf-amplicon \
    --fastq wf-amplicon-demo/fastq \
    --reference wf-amplicon-demo/reference.fa \
    -profile standard

For further information about running a workflow on the command line see https://labs.epi2me.io/wfquickstart/

Related protocols

This workflow is designed to take input sequences that have been produced from Oxford Nanopore Technologies devices.

Find related protocols in the Nanopore community.

Inputs

Input Options

Nextflow parameter name Type Description Help Default
fastq string FASTQ files to use in the analysis. This accepts one of three cases: (i) the path to a single FASTQ file; (ii) the path to a top-level directory containing FASTQ files; (iii) the path to a directory containing one level of sub-directories which in turn contain FASTQ files. In the first and second case, a sample name can be supplied with --sample. In the last case, the data is assumed to be multiplexed with the names of the sub-directories as barcodes. In this case, a sample sheet can be provided with --sample_sheet.
analyse_unclassified boolean Analyse unclassified reads from input directory. By default the workflow will not process reads in the unclassified directory. If selected and if the input is a multiplex directory the workflow will also process the unclassified directory. False
reads_downsampling_size integer Downsample to this number of reads per sample. Downsampling is performed after filtering. Downsampling is performed by default to improve performance. Set to 0 to disable downsampling and use all data for analysis. Increasing the downsampling size (or setting it to zero) may lead to excessive memory consumption. 1500
reference string Path to a reference FASTA file. The reference file should contain one sequence per amplicon.

Sample Options

Nextflow parameter name Type Description Help Default
sample_sheet string A CSV file used to map barcodes to sample aliases. The sample sheet can be provided when the input data is a directory containing sub-directories with FASTQ files. The sample sheet is a CSV file with, minimally, columns named barcode and alias. Extra columns are allowed. A type column is required for certain workflows and should have the following values; test_sample, positive_control, negative_control, no_template_control.
sample string A single sample name for non-multiplexed data. Permissible if passing a single .fastq(.gz) file or directory of .fastq(.gz) files.

Pre-processing Options

Nextflow parameter name Type Description Help Default
min_read_length integer Shorter reads will be removed. 300
max_read_length integer Longer reads will be removed.
min_read_qual number Reads with a lower mean quality will be removed. 10
drop_frac_longest_reads number Drop fraction of longest reads. The very longest reads might be concatemers or contain other artifacts. In many cases removing them simplifies de novo consensus generation. 0.05
take_longest_remaining_reads boolean Whether to use the longest (remaining) reads. With this option, reads are not randomly selected during downsampling (potentially after the longest reads have been removed), but instead the longest remaining reads are taken. This generally improves performance on long amplicons. True
min_n_reads number Samples / barcodes with fewer reads will not be processed. 40

Variant Calling Options

Nextflow parameter name Type Description Help Default
min_coverage integer Minimum coverage for variants to keep. Only variants covered by more than this number of reads are reported in the resulting VCF file. 20
basecaller_cfg string Name of the basecaller model that processed the signal data; used to select an appropriate Medaka model. The basecaller configuration is used to automatically select the appropriate Medaka model. The automatic selection can be overridden with the 'medaka_model' parameters. Available models are: 'dna_r10.4.1_e8.2_400bps_hac@v3.5.2', 'dna_r10.4.1_e8.2_400bps_sup@v3.5.2', 'dna_r9.4.1_e8_fast@v3.4', 'dna_r9.4.1_e8_hac@v3.3', 'dna_r9.4.1_e8_sup@v3.3', 'dna_r10.4.1_e8.2_400bps_hac_prom', 'dna_r9.4.1_450bps_hac_prom', 'dna_r10.3_450bps_hac', 'dna_r10.3_450bps_hac_prom', 'dna_r10.4.1_e8.2_260bps_hac', 'dna_r10.4.1_e8.2_260bps_hac_prom', 'dna_r10.4.1_e8.2_400bps_hac', 'dna_r9.4.1_450bps_hac', 'dna_r9.4.1_e8.1_hac', 'dna_r9.4.1_e8.1_hac_prom'. dna_r10.4.1_e8.2_400bps_sup@v4.2.0
medaka_model string The name of the Medaka model to use. This will override the model automatically chosen based on the provided basecaller configuration. The workflow will attempt to map the basecaller model (provided with 'basecaller_cfg') used to a suitable Medaka model. You can override this by providing a model with this option instead.

De-novo Consensus Options

Nextflow parameter name Type Description Help Default
force_spoa_length_threshold integer Consensus length below which to force SPOA consensus generation. If the consensus generated by miniasm is shorter than this value, force consensus generation with SPOA (regardless of whether the sequence produced by miniasm passed QC or not). The rationale for this parameter is that miniasm sometimes gives slightly truncated assemblies for short amplicons from RBK data, whereas SPOA tends to be more robust in this regard. 2000
spoa_minimum_relative_coverage number Minimum coverage (relative to the number of reads per sample after filtering) when constructing the consensus with SPOA. Needs to be a number between 0.0 and 1.0. The result of multiplying this number with the number of reads for the corresponding sample (after filtering) is passed on to SPOA's --min-coverage option. 0.15
minimum_mean_depth integer Mean depth threshold to pass consensus quality control. Draft consensus sequences with a lower average depth of coverage after re-aligning the input reads will fail QC. 30
primary_alignments_threshold number Fraction of primary alignments to pass quality control. Draft consensus sequences with a lower fraction of primary alignments after re-aligning the input reads will fail QC. 0.7

Output Options

Nextflow parameter name Type Description Help Default
out_dir string Directory for output of all workflow results. output
combine_results boolean Whether to merge per-sample results into a single BAM / VCF file. Per default, results are grouped per sample. With this option, an additional BAM and VCF file are produced which contain the alignments / variants for all samples and amplicons. False

Advanced Options

Nextflow parameter name Type Description Help Default
number_depth_windows integer Number of windows used during depth of coverage calculations. Depth of coverage is calculated for each sample across each amplicon split into this number of windows. A higher number will produce more fine-grained plots at the expense of run time. 100
medaka_target_depth_per_strand integer Downsample each amplicon to this per-strand depth before running Medaka. Medaka performs best with even strand coverage and depths between 80X and 400X. To avoid too high coverage, the workflow downsamples the reads for each amplicon to this per-strand depth before running Medaka. Changing this value is discouraged as it might cause decreased performance. 150

Miscellaneous Options

Nextflow parameter name Type Description Help Default
threads integer Maximum number of CPU threads to use per workflow task. Several tasks in this workflow benefit from using multiple CPU threads. This option sets the maximum number of CPU threads for such processes. The total CPU resources used by the workflow are constrained by the executor configuration in nextflow.config. 4
disable_ping boolean Enable to prevent sending a workflow ping. False

Outputs

Outputs files may be aggregated including information for all samples or provided per sample. Per-sample files will be prefixed with respective aliases and represented below as {{ alias }}.

Title File path Description Per sample or aggregated
workflow report ./wf-amplicon-report.html Report for all samples. aggregated
Sanitized reference file ./reference_sanitized_seqIDs.fasta Some programs used by the workflow don't like special characters (like colons) in the sequence IDs in the reference FASTA file. The reference is thus "sanitized" by replacing these characters with underscores. This file is only generated when the workflow is run in variant calling mode. aggregated
Alignments BAM file ./{{ alias }}/alignments/aligned.sorted.bam BAM file with alignments of input reads against the references (in variant calling mode) or the created consensus (in de-novo consensus mode). per-sample
Alignments index file ./{{ alias }}/alignments/aligned.sorted.bam.bai Index for alignments BAM file. per-sample
De-novo consensus FASTQ file ./{{ alias }}/consensus/consensus.fastq Consensus file generated by de-novo consensus pipeline. per-sample
Consensus FASTA file ./{{ alias }}/consensus/consensus.fasta Consensus file generated variant calling pipeline. per-sample
Variants VCF file ./{{ alias }}/variants/medaka.annotated.vcf.gz VCF file of variants detected against the provided reference. per-sample
Variants index file ./{{ alias }}/variants/medaka.annotated.vcf.gz.csi Index for variants VCF file. per-sample

Pipeline overview

Note: The initial preprocessing steps are the same for the variant calling and the de-novo consensus mode.

1. Read preprocessing

The input data can be a single FASTQ file, a directory containing FASTQ files, or a directory containing barcoded sub-directories which in turn contain FASTQ files. A sample sheet can be included with --sample_sheet and a sample name for an individual sample with --sample. If a sample sheet is provided, it needs to contain at least these three columns:

  • barcode: names of the sub-directories with the FASTQ files of the different samples
  • alias: sample names
  • type: sample types (needs to be one of test_sample, positive_control, negative_control, no_template_control)

After parsing the sample sheet, the raw reads are filtered. Relevant options for filtering are

  • --min_read_length
  • --max_read_length
  • --min_read_qual

Reads can optionally also be downsampled (--reads_downsampling_size controls the number of reads to keep per sample). The workflow supports random downsampling as well as selecting reads based on read length. Subsetting based on read length tends to work better for de-novo consensus generation and usually does not decrease performance of the variant calling mode. It is thus set as default (see the FAQ section below for details and for how to disable this). The selected reads are then trimmed with Porechop prior to downstream analysis.

Note: Samples with fewer reads than --min_n_reads after preprocessing are ignored.

Variant calling mode

2. Align reads

Preprocessed reads are aligned against the provided reference with Minimap2 (please note that the reference should only contain the expected sequences of the individual amplicons). Bamstats is used to collate alignment statistics and mosdepth to calculate the depth of coverage along the amplicon.

3. Call variants

After alignment, haploid variants are called with Medaka. You can set the minimum coverage a variant needs to exceed in order to be included in the results with --min_coverage. Variants with lower coverage will still be listed in the resulting VCF files, but with LOW_DEPTH instead of PASS in the FILTER column.

The workflow selects the appropriate Medaka models based on the basecaller configuration that was used to process the signal data. You can use the parameter --basecaller_cfg to provide this information (e.g. dna_r10.4.1_e8.2_400bps_hac). Alternatively, you can choose the Medaka model directly with --medaka_model.

4. Use the variants to generate a consensus

The variants passing the depth filter are then incorporated in the reference to create the consensus sequence.

De-novo consensus mode

2. Create a draft consensus

When running in de-novo mode, miniasm or SPOA are used to create a draft consensus after the reads were selected and trimmed. miniasm tends to work better for longer amplicons and spoa for shorter amplicons. The workflow attempts to create an assembly with miniasm first. If this succeeds, the draft assembly is polished with Racon and the input reads are re-aligned against it. This is followed by some post-processing (trimming low-coverage regions from the ends) and quality control (QC). During QC, the following sanity-checks are performed:

  • The mean coverage of the consensus needs to be above --minimum_mean_depth (default: 30X).
  • The fraction of primary alignments for the re-aligned reads needs to be more than --primary_alignment_threshold (default: 70%). Large numbers of secondary / supplementary alignments indicate that something might have gone wrong during assembly. If your amplicons contain long repetitive regions, you can lower this number.

If more than one contig from the draft assembly passes these filters, the one with the highest coverage is selected.

If assembly generation fails or none of the contigs produced by miniasm pass QC, spoa is tried. Regardless of how the draft consensus was generated (miniasm or spoa), a final polishing step with Medaka is performed.

Note: Since spoa tends to produce a better consensus than miniasm for short amplicons, users can force the workflow to run spoa if the assembly created by miniasm is shorter than --force_spoa_length_threshold (even if it passes QC).

Troubleshooting

  • If the workflow fails please run it with the demo data set to ensure the workflow itself is working. This will help us determine if the issue is related to the environment, input parameters or a bug.
  • Please see here for how to resolve some common Nextflow issues and here for how to interpret command exit codes.

FAQ's

Variant calling mode: How can I specify specific reference sequences for individual barcodes? - Per default, the workflow aligns all barcodes against all sequences in the supplied reference. If you want to map specific reference sequences to specific amplicons, you can add a column named ref containing the respective target reference IDs to the sample sheet. If a barcode should be aligned against multiple reference sequences, their IDs can be included as a space-delimited list. If a specific sample should be aligned against all references, you can leave the corresponding cell in the ref column blank. Consider the following example with 4 barcodes and 2 sequences in the reference file. The sample sheet tells the workflow that the first two barcodes (sample1 and sample2) are expected to contain reads from both amplicons in the reference, whereas the other two samples only contain one amplicon each.

barcode,alias,type,ref
barcode01,sample1,test_sample,katG::NC_000962.3:2154725-2155670 rpoB::NC_000962.3:760285-761376
barcode02,sample2,test_sample,
barcode03,sample3,positive_control,katG::NC_000962.3:2154725-2155670
barcode04,sample4,test_sample,rpoB::NC_000962.3:760285-761376

How much coverage do I need? - We recommend >150X average coverage across the individual amplicons. 1500 reads per amplicon should thus be enough in the vast majority of cases. You can speed up execution time by setting --reads_downsampling_size 1500 (or to a smaller number if your amplicons are not longer than a few kb).

Why does the workflow select reads based on length rather than random downsampling per default? - Despite the workflow dropping reads containing adapter sequences in the middle (using porechop --discard_middle), some reads in the input data stemming from concatemers or other PCR artifacts might still make it through preprocessing and could thus interfere with consensus generation. A simple way to avoid this is to drop a small fraction (e.g. 5%) of longest reads. Furthermore, spoa depends on the order of reads in the input and benefits from "seeing" longer reads first. Therefore, the following workflow options are used per default --drop_frac_longest_reads 0.05 --take_longest_remaining_reads. This essentially drops the longest 5% of reads and then takes selects the next longest reads (either all of them or the number specified with --reads_downsampling_size). To disable the default behaviour and enforce random downsampling of input reads, use --drop_frac_longest_reads 0 --take_longest_remaining_reads false.

Is there a difference between the consensus sequences created in variant calling and de-novo consensus mode? - In variant calling mode, the consensus sequence is generated by applying the variants found by Medaka to the provided reference. This comes with the caveat that structural variants too large to be detected by Medaka are not going to be represented in the consensus. For this reason we suggest to always have a look at the coverage plots in the generated HTML report. In de-novo consensus mode, however, the consensus is generated either via assembly or POA and no prior information besides the reads is taken into account.

If your question is not answered here, please report any issues or suggestions on the github issues page or start a discussion on the community.