The goal if this respository is to provide information about using the local API available on some solar edge inverters. This is a WIP based on my observations and may contain inaccuracies. Pull Requests or Issues are encouraged to correct any mistakes or add additonal informatoin.
The local API is available on the SExxxxH-US models with SetApp as well as European three phase inverters SEXXK-XXXTXBXX4 models with SetApp like SE3K-E10K, SE12.5K-SE27.6K and SE33.3K. Same goes for Australian inverters SE2500H->SE10000H. Please check carefully the datasheets if in the section "Additional Features", sub-section "Inverter Commissioning" is present the following line "With the SetApp mobile application using built-in Wi-Fi access point for local connection".
More inforation on SetApp could be found here. These models have no LED screen and are provisioned ONLY via a phone app during commissioning. Check also the SetApp FAQ for more info. For convenience it is reported here one Q&A:
Q: Can the new app be used for already installed inverters?
A: Only SolarEdge inverters with a new communication board (no display) can be activated or configured via SetApp.
These new inverters have a CPU number starting with 04.
You can check by finding the IP address of your inverter and visiting it in a browser. If it supports the local API, you'll see the SolarEdge logo and a "Commissioning" menu.
If you do not have the local API available, see this repository as an alternative.
For convinience, a python API wrapper, solaredge_local is available. Only python 3 is supported
To install: pip3 install solaredge-local
To use:
from solaredge_local import SolarEdge
client = SolarEdge("http://<inverter ip address>")
client.get_status() # Provides general energy and other overview information
client.get_maintenance() # Provides optimizer level information and other details
client.get_information() # Provides software versions and error log list.
client.get_power_control() # Provides power control information and other details.
- AppConfigs: "web/v1/app_configs"
- Region: "web/v1/region"
- Region_Country: "web/v1/region/country"
- Region_Language: "web/v1/region/language"
- Pairing: "web/v1/pairing"
- Pairing_Request: "web/v1/pairing/request"
- Communication: "web/v1/communication"
- Communication_Server: "web/v1/communication/server"
- Communication_Lan: "web/v1/communication/lan"
- Communication_Rs485_SlaveDetect: "web/v1/communication/rs485//slave_detect"
- Communication_Rs485_Protocol: "web/v1/communication/rs485//protocol"
- Communication_Rs485_DeviceId: "web/v1/communication/rs485//deviceid"
- Communication_Rs485_Modbus: "web/v1/communication/rs485//modbus"
- Communication_Rs485_Modbus_AddDevice: "web/v1/communication/rs485//modbus/add_device"
- Communication_Rs485_Modbus_RemoveDevice: "web/v1/communication/rs485//modbus/remove_device"
- Communication_Wifi: "web/v1/communication/wifi"
- Communication_Wifi_Wps: "web/v1/communication/wifi/wps"
- Communication_Wifi_Connect: "web/v1/communication/wifi/connect"
- Communication_Cellular: "web/v1/communication/cellular"
- Communication_Zigbee_Defaults: "web/v1/communication/zigbee/defaults"
- Communication_Zigbee_ModuleConfigs: "web/v1/communication/zigbee/module_configs"
- Communication_Zigbee_OpMode: "web/v1/communication/zigbee/op_mode"
- Communication_Gpio_Pri: "web/v1/communication/gpio/pri"
- Communication_ModbusTcp: "web/v1/communication/modbus_tcp"
- PowerControl: "web/v1/power_control"
- PowerControl_GridControl: "web/v1/power_control/grid_control"
- PowerControl_EnergyManager_LimitControl: "web/v1/power_control/energy_manager/limit_control"
- PowerControl_EnergyManager_EnergyControl: "web/v1/power_control/energy_manager/energy_control"
- PowerControl_EnergyManager_StorageControl: "web/v1/power_control/energy_manager/storage_control"
- PowerControl_ReactivePower: "web/v1/power_control/reactive_power"
- PowerControl_ActivePower: "web/v1/power_control/active_power"
- PowerControl_Wakeup: "web/v1/power_control/wakeup"
- PowerControl_Advanced: "web/v1/power_control/advanced"
- PowerControl_Reset: "web/v1/power_control/reset"
- PowerControl_Rrcr: "web/v1/power_control/rrcr"
- Maintenance: "web/v1/maintenance"
- Maintenance_DateTime: "web/v1/maintenance/date_and_time"
- Maintenance_ResetCounters: "web/v1/maintenance/reset_counters"
- Maintenance_ResetFactory: "web/v1/maintenance/reset_factory"
- Maintenance_Afci: "web/v1/maintenance/afci"
- Maintenance_AfciTest: "web/v1/maintenance/afci/test"
- Maintenance_Inverters_SelfTest: "web/v1/maintenance/inverters//self_test"
- Maintenance_Standby: "web/v1/maintenance/standby"
- Maintenance_GridProtectionLogin: "web/v1/maintenance/grid_protection/login"
- Maintenance_GridProtection: "web/v1/maintenance/grid_protection"
- Maintenance_UpgradeUsb: "web/v1/maintenance/fw_upgrade/usb"
- Information: "web/v1/information"
- Status: "web/v1/status"
- Status_ServerCommTest: "web/v1/status/server_comm_test"
The Status endpoint appears to the most useful for realtime production data. Optimizer level data is available from the Maintenance API endpoint.
All endpoints I have explored so far appear to be a GET, and responses use Protocol Buffers. There is no authentication.
You can see the raw data by doing the following (assuming you have the protoocal buffers CLI tool installed)
curl -s http://<inverter ip>/web/v1/status | protoc --decode_raw
Many numbers appear to be 32 bit floating point.
The proto definitions required to fully parse the responses are available in javascript if you choose "view source" in the developer tools of your browser.
If there is a corresponding .proto
file in message_types, you can view the parsed response from the API. Each proto file correspond to the name of an API endpoint. These are very much a WIP and may be incomplete. These can be created by choosing "view source" in the developer tools of your browser, and searching for text like proto.web_status.<apiNameInCamelCase>.toObject
Here is an example for the status API:
curl -s http://<inverter ip>/web/v1/status | protoc --decode Status message_types/status.proto
To add or change the Protocol Buffer defintions, please do the following
-
Manually change the
message_types/*.proto
files as required -
Test the file using
curl
as described in View Parsed Response -
Update the generated
*_pb2.py
files for each file changed by running a command like:protoc -I=message_types --python_out=solaredge_local message_types/<filename_changed>.proto
-
Commit the generated updates