Big Ten Two-Zone Homogenized Benchmark IEU-MET-FAST-007
Closed this issue · 1 comments
shabudarda commented
Why do I get ERROR: Maximum number of lost particles has been reached. Please reply.
<cell id="1" material="1" region="-1 3 -4" /> <!-- Central Core -->
<cell id="2" material="2" region=" -2 5 -6 1 -3 4" /> <!-- Reflector -->
<surface id="1" type="z-cylinder" coeffs="0. 0. 26.67" />
<surface id="2" type="z-cylinder" coeffs="0. 0. 41.91" boundary="vacuum" />
<surface id="3" type="z-plane" coeffs="-28.8169" />
<surface id="4" type="z-plane" coeffs="28.8169" />
<surface id="5" type="z-plane" coeffs="-48.2600" />
<surface id="6" type="z-plane" coeffs="48.2600" />
material is
<!-- Intermediate Enriched Uranium (10 wt%) -->
<material id="1">
<density units="sum" />
<nuclide name="U234" ao="2.4761e-05" />
<nuclide name="U235" ao="4.8461e-03" />
<nuclide name="U236" ao="4.3348e-05" />
<nuclide name="U238" ao="4.2695e-02" />
</material>
<!-- Depleted Uranium -->
<material id="2">
<density units="sum" />
<nuclide name="U234" ao="2.8672e-07" />
<nuclide name="U235" ao="1.0058e-04" />
<nuclide name="U236" ao="1.1468e-06" />
<nuclide name="U238" ao="4.7677e-02" />
</material>
and setting is
<!-- Parameters for k-eigenvalue calculation -->
<run_mode>eigenvalue</run_mode>
<batches>50</batches>
<inactive>5</inactive>
<particles>1000</particles>
<!-- Starting source -->
<source>
<space type="box" parameters="-1 -1 -1 1 1 1" />
</source>
paulromano commented
Response given in #35