/ATC_MiThermometer

Custom firmware for the Xiaomi Thermometer LYWSD03MMC and Telink Flasher via USB to Serial converter

Primary LanguageC

ATC_MiThermometer

Custom firmware for the Xiaomi Thermometer LYWSD03MMC and Telink Flasher via USB to Serial converter

This repo is made together with this explanation video:(click on it)

YoutubeVideo

It is possible to update the Firmware of the Xiaomi Thermometer OTA with this WEB Tool i wrote: https://atc1441.github.io/TelinkFlasher.html

The web flasher does work for many devices that uses the Telink TLSR82** MCUs and it can also be used to reflash the Stock firmware back to the device.

You can support my work via PayPal: https://paypal.me/hoverboard1 this keeps projects like this coming.

Tutorial in spanish: https://domoticaencasa.es/tutorial-custom-firmware-termohigrometro-xiaomi-lywsd03mmc Thanks to Eduardo Ruiz

OTA

How to flash the custom firmware:

Download the ATC_Thermometer_custom.bin file and open the Web Flasher, connect to the Xiaomi thermometer, searching may take a while as it broadcasts not so often for better battery life, after the connection is successful click on Do Activation to Authorize the Connection, while its doing so you can already select the firmware file. Be careful to select the right one as it's not possible to check the firmware further. Then click on start flashing to flash the new firmware to the Thermometer.

After the flashing is done the device should reboot, if the screen stays off pull the battery out for a short amount of time.

To flash the stock firmware back to the Thermometer just open that one while flashing.

USB to UART

How to flash the custom firmware or unbrick the device:

To flash new firmware via an standard USB to UART adapter simply connect the Thermometer as seen in the picture "Mi_SWS_Connection.jpg" to the USB to UART converter and run the ATCtelink.py tool with the first command to be the file you want to flash.

Example: "python3 ATCtelink.py ATC_Thermometer.bin"

it the flashing fails or no valid COMport can be found you can edit it in the Python script also try to increase the ResetTime, i will try to make that nicer in future! So far it turned out that flashing via MAC does not work correctly, i think that is because the data will not get pushed out in real time so the Emulated SWS protocoll gets interrupted.

The UART flasher software uses code base from https://github.com/pvvx/TlsrComSwireWriter. Thanks to pvvx for its awesome work on this !

Custom firmware:

To build the custom firmware on your own follow this guide to get a working TC32 Compiler environment ready where you can add the Custom Mi firmware https://github.com/Ai-Thinker-Open/Telink_825X_SDK use google translate for better reading experience. Try to "make" the blink example included in the SDK once to see if the compiling works as it should. You can then copy the folder "ATC_Thermometer" into the example folder and go into that with the terminal now do a "make" and it will build the custom firmware. The newly created .bin file can then simply be flashed by either the Web Flasher or the USB to UART method.

Because of the OTA dual bank update method a firmware can be maximum 256kB in size.

The MCU used in the Thermometer is the TLSR8251 the datasheet can be found here: http://wiki.telink-semi.cn/doc/ds/DS_TLSR8251-E_Datasheet%20for%20Telink%20BLE+IEEE802.15.4%20Multi-Standard%20Wireless%20SoC%20TLSR8251.pdf

Getting the MAC of your Thermometer:

On boot the custom firmware will show the last three bytes of the MAC Address in the humidity display part on the LCD for 2 seconds each, the first three bytes are always the same so not shown. Also the BLE name will include the last three bytes of the MAC Address

Settings in custom firmware:

The following settings can be send to the RxTx Characteristics 0x1F10/0x1f1f These settings will not get saved on power loss, maybe that will change in future but normaly the battery will be in there for a while

Show battery level in LCD :

Will show Humidity% or Battery% flipping back and forth every 5~6 seconds, with battery symbol at bottom indicated it's battery level

The battery level will be shown on the LCD every 5-6secdonds indicated by the battery symbol at the humidity display.

0xB1 = Enabled <- Default

0xB0 = Disabled

Change display to °F or °C:

0xFF = Lcd in °F

0xCC = Lcd in °C <- Default

Blinking smiley:

0xA0 = Smiley off

0xA1 = Smiley happy

0xA2 = Smiley sad

0xA3 = Comfort Indicator

0xAB = Smiley bliking <- Default

Advertising type:

0xAE = Custom <- Default

0xAF = Mi Like

Advertising interval

byte0 0xFE

byte1 0x06 - value times 10 seconds = interval 60 seconds default.

Temp and Humi offset

byte0 0xFA = Temp offset

byte0 0xFB = Humi offset

byte1 as an int8_t

so Temp = range -12,8 - + 12,8 °C offset Humi = range -50 - +50 % offset

Temp or Humi instant advertising

When the temp or Humidity does change to fast between the main loop(5 seconds interval) the Advertising will be instant for that one.

byte0 0xFC = temp_alarm_point // value divided by 10 for temp in °C

byte0 0xFD = humi_alarm_point

byte1 as int8_t

Temp alarm from 0,1°C to 25,5°C Range <- 0,5°C Default

Humi alarm from 1% to 50% Range <- 5% Default

Advertising format of the custom firmware:

The custom firmware sends every minute an update of advertising data on the UUID 0x181A with the Tempereature, Humidity and Battery data.

The format is like this:

Byte 5-10 mac in correct order

Byte 11-12 Temperature in int16

Byte 13 Humidity in percent

Byte 14 Battery in percent

Byte 15-16 Battery in mV uint16_t

Byte 17 frame packet counter

0x0e, 0x16, 0x1a, 0x18, 0x00, 0x00, 0x00, 0x00, 0x00, 0x00, 0xaa, 0xaa, 0xbb, 0xcc, 0xdd, 0xdd, 0x00

Using custom firmware with ESPHome

The LYWSD03MMC sensors work directly with ESPHome XiaomiBLE - xiaomi_lywsd03mmc component.

Set "Mi like" advertising on custom firmware. The bindkey is not necessary any more as the payload is not encrypted in the custom firmware. However, since the bindkey is a mandatory parameter, you still need to give it a fake one in the config file. It can be anything though, as long as it is formatted like a real one.

Details: esphome/feature-requests#552 (comment)

Stock firmware:

Inside this .zip can be found the stock firmware to go back https://github.com/custom-components/sensor.mitemp_bt/files/4022697/d4135e135443ba86e403ecb2af2bf0af_upd_miaomiaoce.sensor_ht.t2.zip

Building manual for docker:

https://github.com/AlmightyFrog/BuildEnvironmentATCMiThermometer

Many thanks to:

@danielkucera https://github.com/danielkucera/mi-standardauth/blob/master/provision.py

@romanhosek https://twitter.com/romanhosek https://github.com/hosek