Unless required by applicable law or agreed to in writing, software distributed under the License is distributed on an "AS IS" BASIS, WITHOUT WARRANTIES OR CONDITIONS OF ANY KIND, either express or implied. See the License for the specific language governing permissions and limitations under the License.

Intro

The autotools of this requires the autoconf-archive package for your system

This is a protocol description using the mailbox registers on Aspeed 2400/2500 chips for managing the LPC Firmware space.

Hardware Details

The mailbox consists of 16 (8 bit) data registers (see Layout for their use). Mailbox interrupt enabling, masking and triggering is done using a pair of control registers, one accessible by the host and the other by the BMC. Interrupts can also be raised per write to each data register, for BMC and host. Write tiggered interrupts are configured using two 8 bit registers where each bit represents a data register and if an interrupt should fire on write. Two 8 bit registers are present to act as a mask for write triggered interrupts.

Low Level Protocol Flow

The protocol itself consists of:

1. Commands sent from the Host to the BMC
2. Responses sent from the BMC to the Host
3. Asyncronous events raised by the BMC.

Sending commands (Host -> BMC)

To initiate a request the host must set a command code (see Commands) into mailbox data register 0. It is also the hosts responsibility to generate a unique sequence number into mailbox register 1. After this any command specific data should be written (see Layout). The host must then generate an interrupt to the BMC by using bit 0 of its control register and wait for an interrupt in the response. Generating an interrupt automatically sets bit 7 of the corresponding control register. This bit can be used to poll for messages.

On receiving an interrupt (or polling on bit 7 of its Control Register) the BMC should read the message from the general registers of the mailbox and perform the necessary action before responding. On responding the BMC must ensure that the sequence number is the same as the one in the request from the host. The BMC must also ensure that mailbox data regsiter 13 is a valid response code (see Responses). The BMC should then use its control register to generate an interrupt for the host to notify it of a response.

Sending Responses (BMC -> Host)

BMC to host communication is also possible for notification of events from the BMC. This requires that the host have interrupts enabled on mailbox data register 15 (or otherwise poll on bit 7 of mailbox status register 1). On receiving such a notification the host should read mailbox data register 15 to determine the event code was set by the BMC (see BMC Event notifications in Commands for detail). After performing the necessary action the host should send a BMC_EVENT_ACK message to the BMC with which bit it has actioned.

High Level Protocol Flow

The commands from the Host fall into rougly three categories:

1. Informational
2. Window management
3. Write handling

The "window" refers to the part of the LPC FW space that has defined contents. The Host cannot make any assumptions about the contents of the FW space outside of the window and the Host must not write to a window that has been opened for reading. The exact behaviour of accessing outside the window is explictly undefined by the protocol to allow some flexibility in how the BMC implements the protocol.

The Host opens a window using the ```CREATE_READ_WINDOW''' or

issuing a ```CREATE_*_WINDOW command''' will forcibly close the existing window
even if opening the new window fails. The Host specifies the location inside the
flash that it wishes to access for either reading or writing as a part of the
command, and may provide a hint indicating how large the window should be.
However, the BMC is free to ignore this. As a part of the response the BMC
provides the offset into the FW space where the window begins and the actual
size of the window.

## Read Handing

This window design allows read window requests to be serviced by exposing
the entire SPI Flash MMIO range on the LPC FW space. The advantage of the
window method over directly mapping the entire flash is that it allows us to
selectively overwrite parts of flash without reprogramming the backing storage.
This is convnienet 

## Write Handling

Write handling is somewhat more complicated because the BMC has no way to
determine when the Host has written into the FW space. The Host sends the
MARK_DIRTY command to notify the BMC which parts of the write window have
been updated. Once marked the BMC may write the window contents to permernant
storage (if required) at any time. Alternatively, the Host can force a flush
with the WRITE_FLUSH command, or by closing the window.

---

## Layout

Byte 0: COMMAND Byte 1: Sequence Byte 2-12: Arguments Byte 13: Response code Byte 14: Host controlled status reg Byte 15: BMC controlled status reg

## Commands

RESET_STATE 1 GET_MBOX_INFO 2 GET_FLASH_INFO 3 CREATE_READ_WINDOW 4 CLOSE_WINDOW 5 CREATE_WRITE_WINDOW 6 MARK_WRITE_DIRTY 7 WRITE_FLUSH 8 BMC_EVENT_ACK 9

## Sequence
Unique message sequence number to be allocated by the host at the
start of a command/response pair. The BMC must ensure the responses to
a particular message contain the same sequence number that was in the
request from the host.

## Responses

SUCCESS 1 PARAM_ERROR 2 WRITE_ERROR 3 SYSTEM_ERROR 4 TIMEOUT 5


## Information
- All multibyte messages are LSB first(little endian)
- All responses must have a valid return code in byte 13

Only one window can be open at once.

### Commands in detail
Command:
	RESET_STATE
	Data:
		-
	Response:
		-
	Notes:
		This command is designed to inform the BMC that it should put
		host LPC mapping back in a state where the SBE will be able to
		use it. Currently this means pointing back to BMC flash
		pre mailbox protocol. Final behavour is still TBD.


Command:
	GET_MBOX_INFO
	Arguements:
		Args 0: API version

	Response:
		Args 0: API version
		Args 1-2: default read window size as number of blocks
		Args 3-4: default write window size as number of block
		Args 5: Block size as power of two.


Command:
	CLOSE_WINDOW
	Arguments:
		-
	Response:
		-
	Notes:
		Closes active window. Renders the LPC mapping unusable.
		If the current window is a write window any dirty data
		will be flushed.

Command:
	GET_FLASH_INFO
	Arguments:
		-
	Response:
		Args 0-3: Flash size in bytes
		Args 4-7: Erase granule in bytes

		XXX: Why is this in bytes?


Command:
	CREATE_WRITE_WINDOW
	CREATE_READ_WINDOW
	Arguments:
		Args 0-1: Read window offset as number of blocks
		Args 2-3: Requested read window size in blocks. (v2)
	Response:
		Args 0-1: Start block of this window on the LPC bus
		Args 2-3: Actual size of the window in blocks. (v2)
	Notes:
		The requested window size is only a hint. The response
		indicates the actual size of the window. The BMC may
		want to use the requested size to pre-load the remainder
		of the request.

		The requested window size may be zero. In this case the
		BMC should use the default size returned by the
		GET_MBOX_INFO command. This behaviour makes v1 and v2
		implementations to be compatible.

		The format of the CREATE_{READ,WRITE}_WINDOW commands
		are identical.


Command:
	MARK_WRITE_DIRTY
	Data:
		Data 0-1: Where within window as number of blocks
			What the fuck? On what planet is <blocks, bytes> useful?
		Data 2-5: Number of dirty bytes
	Response:
		-
	Notes:
		The BMC has no method for intercepting writes that occur
		over the LPC bus. The Host must explicitly notify the
		where and when a write has occured so that it may flush
		it to persistence.

		This command accepts a <bytes, bytes> arguments rather
		than blocks to allow finer grained handling of writes.
		The BMC is free to mark entire blocks as dirty in response
		to this command.

		Where within the window is the index of the first dirty
		block within the window - zero refers to the first block of
		the mapping.
		This command marks bytes as dirty but does not nessesarily
		flush them to flash. It is expected that this command will
		respond quickly without actually performing a write to the
		backing store.


Command:
	WRITE_FLUSH
	Data:
		-
	Response:
		-
	Notes:
		Flushes any data in the current window that has been
		marked dirty.

Command:
	ERASE (v2 only)
	Data:
		0-1: Window block offset
		2-3: block count
	Response:
		-
	Notes:
		Some applications assume Flash-like semantics where
		writes must be preceeded by an erase. This command
		provides a fast method for erasing blocks so the Host
		does not have to emulate these semantics over the LPC.

		Additionally marks the blocks as dirty. The BMC may
		delay doing the actual erase until a FLUSH.

		XXX: Should we nail down this more and force the BMC to
		     set the contents of an erased block to 0xFFs. I
		     think that's what pflash expects.

		XXX: How does this interact with the window? Looks like
		     we're forcing the BMC to do a RMW cycle under the
		     hood if the write window is not aligned to the
		     erase granule. That's ok I suppose.

Command:
	BMC_EVENT_ACK
	Data:
		Bits in the BMC status byte (mailbox data register 15) to ack
	Response:
		*clears the bits in mailbox data register 15*
		-
	Notes:
		The host will use this command to acknowledge BMC events
		supplied in mailbox register 15.


BMC notifications:
	If the BMC needs to tell the host something then it simply
	writes to Byte 15. The host should have interrupts enabled
	on that register, or otherwise be polling it.
	 -[bit 0] BMC reboot. A BMC reboot informs the host that its
	  windows/dirty bytes/in flight commands will be lost and it
	  should attempt to reopen windows and rewrite any data it had
	  not flushed.
	Futhur details TBD