Issues
- 0
Support DanglingLineAction in OperatorStrategies
#1102 opened by jeandemanged - 0
- 0
Security Analysis: custom redistribution of injections lost by the contingency
#1092 opened by jeandemanged - 0
- 0
- 0
SecurityAnalysis: Reconfigure slack distribution outer loops per contingency using an extension
#1091 opened by jeandemanged - 0
- 0
- 0
DC Loadflow: Wrong bus P balance if PST connected. (equation eval ignores constant terms)
#1137 opened by vmouradian - 0
Extrapolate maxQ and minQ reactive limits when outside active power limits in ReactiveCapabilityCurve
#1143 opened by SylvestreSakti - 0
Add the violation location in voltage LimitViolations
#1133 opened by jamal-khey - 0
- 0
Bug: Multi-slack not handled in DC but can happen if used for AC voltage init
#1117 opened by vmouradian - 3
Area Interchange Control as OuterLoop
#978 opened by jeandemanged - 0
- 3
- 0
Export admittance and Jacobian matrices
#1086 opened by AnkurArohi - 1
The active power control regulation of the PST does not give the target flow with DC load flow
#1045 opened by WalAmeni - 0
Support of `Battery` contingency
#1015 opened by annetill - 1
Static var compensator with regulation mode OFF
#913 opened by annetill - 0
Slack bus relocation
#930 opened by annetill - 1
Hvdc AC emulation: support of -Pmax/Pmax
#1016 opened by annetill - 0
- 1
- 1
Refactor Woodburry matrix identity usage
#767 opened by Hadrien-Godard - 0
Improve incremental outerloops performance
#1007 opened by jeandemanged - 0
Sensistivity analysis: support sensitivity of reactive injection to a voltage setpoint
#989 opened by vidaldid-rte - 7
Target priority configurability for voltage control among generators, transformers and shunts
#954 opened by Hadrien-Godard - 0
Remote phase control for current limiter mode
#1006 opened by annetill - 0
Sensistivity analysis: support sensitivity of voltage magnitude to a reactive injection
#985 opened by vidaldid-rte - 0
Improve tie line state monitor
#972 opened by annetill - 3
- 5
- 1
LfNetwork serialization
#982 opened by flo-dup - 2
Fast restart
#949 opened by annetill - 0
Flow transfer computation
#973 opened by annetill - 0
- 0
- 0
Incremental connectivity
#912 opened by annetill - 0
DC security analysis
#947 opened by annetill - 0
Implementation of limit reductions
#929 opened by annetill - 0
Badly formatted reports
#920 opened by ne0ds - 3
- 0
- 0
- 0
RemoteReactivePowerControl NPE when controlled branch is not in same SynchronousComponent as generator
#832 opened by jeandemanged - 1
- 1
BusBarSection or bus contingency
#629 opened by annetill - 0
Fix corner cases of zero impedance subgraph
#765 opened by flo-dup - 0
Limit memory consumption of sensitivity analysis
#642 opened by geofjamg