LswLogger Binding

This binding lets you connect to LSW logger for Sofar/Omnik/IE for SolarmanPV based on protocol v5 (iGEN tech).

Supported Things

As for now two families of stick loggers are supported.

LSW Logger

Supports following:

Inverter Stick firmware Notes
Sofar Solar: SF4ES005 LSW3_15_FFFF_1.0.57
LSW3_15_FFFF_1.0.65
ME_08_2701_2.06

Please note - some other sticks may be supported by this thing, though they were not tested.

SN23xLoggerV5 (beta - testers and feedback needed)

Inverter Stick firmware Notes
Sofar G3
HYD 5-20KTL-3PH
ZCS Azzurro 3-Phase familiy:
- 3PH HYD6000 ZSS
Note that this won't work if your ZCS inverter is connected via Connext, you have to be using a Wi-Fi or Ethernet Kit such as ZSM-WIFI-USB

This thing is beta

Debug logger (beta)

Supports basically any solarman like logger but it is not designed to expose any particular data. Instead it can be used to tinker around modbus registers exposed by an inverter.

In case of problem with other thing types from the binding, like not drawing appropriate data from your logger/inverter - you may find this thing type useful:

  1. Configure this thingg.
  2. For each pair of register you find should work with your inverter make some tests and note the results:
    • Note values from lastReponse channel
    • Note any logs you catch from the binding
  3. File an issue on github with noted data, and information about your logger (like SN format, firmware version and type) and inverter (name, model, firmware versionm etc).
  4. Wait for my help :)

During setup of this thing you enter serial number of your logger, ip and port along with first and last modbus registers you want to be requested. Then the raw response from the inverter/logger is presented as lastResponse channel.

Currently known registers:

First register Last register Inverter
0x0000 0x0027 SF4ES005
0x0404 0x0420 Sofar G3, HYD 5-20KTL-3PH, ZCS Azzurro 3-Phase (HYD6000 ZSS)
0x0484 0x04AF Same as above
0x0584 0x0589 Same as above
0x0604 0x060A Same as above
0x0684 0x069B Same as above
0x0200 0x0255 Sofar HYD3000/4000/5000/6000-ES
0x10B0 0x10BC Same as above
0x0200 0x0245 Solarman ME3000-SP
0x10B0 0x10BC Solarman ME3000-SP
0x0400 0x042B # ZCS Azzurro 3-phase non-hybrid inverters with LSW-3 WiFi logger with SN 23xxxxxxxx and FW SW3_15_270A_1.53: 3PH 3.3KTL-V3, 3PH 4.4KTL-V3, 3PH 5.5KTL-V3, 3PH 6.6KTL-V3
Not tested, but could probably work: ZCS Azzurro 3PH 8.8KTL-V3, ZCS Azzurro 3PH 11KTL-V3, ZCS Azzurro 3PH 12KTL-V3, SOFAR Solar 4.4KTLX-G3, SOFAR Solar 5.5KTLX-G3, SOFAR Solar 6.6KTLX-G3, SOFAR Solar 8.8KTLX-G3, SOFAR Solar 11KTLX-G3, SOFAR Solar 12KTLX-G3
0x0482 0x04A4 Same as above
0x0582 0x0589 Same as above
0x0682 0x068B Same as above
0x0003 0x0080 SUN600G3 (DEYE/VESDAS), SUN2000G3
0x0003 0x0070 DEYE Hybrid
0x0096 0x00f8 Same as above
0x0003 0x0059 SUN-8/12K-SG04LP3-EU
0x0202 0x022E Same as above
0x024A 0x024F Same as above
0x0256 0x027C Same as above
0x0284 0x028D Same as above
0x02A0 0x02A7 Same as above

Discovery

Binding does not support discovery.

Thing Configuration

Each thing must be configured with following properties

Property Value Description
hostname IP or hostname IP or network resolvable name of your logger stick
port defaults to 8899 Port for communicating with logger, mostly 8899
serialNumber S/N, number Serial number of your stick logger
refreshTime Period in seconds Time between next request for data from logger
retriesCount Count as number Reconnecting tries after which logger will be marked offline
maxOfflineTime Period in minutes Max period in minutes afer which logger is assumed to broken
startRegister First modbus register Only for debug thing. Example value 0x0000
endRegister Last modbus register Only for debug thing. Example value 0x0027

Channels

LSW Logger

Chanel name Description
online Whether inverter is communicating or not
operatingState Possible values: Unknown, Check, Normal, Fault, Permanent
fault This channel will be replaced by a new group - do not use
gridAVoltage DC voltage of the first grid connected to the inverter
gridACurrent DC current of the first grid connected to the inverter
gridBVoltage DC voltage of the second grid connected to the inverter
gridBCurrent DC current of the second grid connected to the inverter
gridAPower Power of the first grid connected to the inverter
gridBPower Power of the second grid connected to the inverter
outputActivePower
outputReactivePower
outputFrequency
1stPhaseVoltage Voltage of the 1st phase generated by inverter
1stPhaseCurrent Current of the 1st phase generated by inverter
2ndPhaseVoltage Voltage of the 2nd phase generated by inverter
2ndPhaseCurrent Current of the 2nd phase generated by inverter
3rdPhaseVoltage Voltage of the 3rd phase generated by inverter
3rdPhaseCurrent Current of the 3rd phase generated by inverter
totalEnergyProduction
totalGenerationTime
todayEnergyProduction
todayGenerationTime
inverterModuleTemperature Module temperature
inverterInnerTemperature Inner temperature

Suppport this project