/aquatemp

Home Assistant AquaTemp Heat Pump Climate Entity

Primary LanguagePython

Home Assistant Aqua Temp & Hi Temp Heat Pumps

This is Home Assistant's an integration for PHINX Aqua Temp / HiTemp compatible heat pumps. It allows controlling temperature, HVAC mode (heat, cool, auto, off) and fan mode (low, auto). It also reports all parameters available in sensors and sensors.

AquaTemp's cloud protocol is based on aquatemp project with additional functionality.

Changelog

How to

Requirements

Account for AquaTemp / HiTemp

Shared device to avoid token expiration when using the App parallel to Integration

Aqua Temp / Hi Temp introduced in v1.5.9 single login "feature" by default, meaning, only one device can be logged in, Following a recommendation from @dodg3r & @kopierschnitte, you can avoid it by creating additional account and sharing the device with that new account.

Switching from 1.x/2.x to 3.x

Requires complete deletion of integration and reinstall after restart HA

Installations via HACS hacs_badge

  • In HACS, look for "Aqua Temp" and install and restart
  • If integration was not found, please add custom repository radical-squared/aquatemp as integration
  • In Settings --> Devices & Services - (Lower Right) "Add Integration"

Setup

To add integration use Configuration -> Integrations -> Add Aqua Temp Integration supports multiple accounts and devices

Fields name Type Required Default Description
Username Textbox + - Username of account
Password Textbox + - Password of account
API Type Dropdown + Aqua Temp (=<1.5.8) API type (where the account was created), available values: Aqua Temp, HiTemp, Aqua Temp (=<1.5.8)
Validation errors
Errors
Invalid credentials (403)

HA Device

Device scheme is according to data from the API

{
  "identifiers": ["aqua_temp", "{DEVICE ID}"],
  "name": "{DEVICE NICK NAME or DEVICE CODE}",
  "device_type": "{DEVICE TYPE}"
}

HA Components

Per device the following components will be generated by default:

Entity Name Parameter Platform Protocol Code?
{HA Device Name} Temperature Unit temperature_unit select False
{HA Device Name} Fault is_fault binary_sensor False
{HA Device Name} Status device_status binary_sensor False
{HA Device Name} API Status api_status binary_sensor False

Per product ID

Additional components are according to following mapping:

Device's Product ID Parameter
Default JSON
Hitemp 1245226668902080512 JSON
AquaTemp 1442284873216843776 JSON

Run API over CLI

Requirements

  • Python 3.10
  • Python virtual environment
  • Install all dependencies, using pip install -r requirements.txt command

Environment variables

Environment Variable Type Default Description
Username String - Username used for Aqua Temp
Password String - Password used for Aqua Temp
DEBUG Boolean False Setting to True will present DEBUG log level message while testing the code, False will set the minimum log level to INFO

Execution

Run file located in tests/main.py

Troubleshooting

Logs

Before opening an issue, please provide logs related to the issue, For debug log level, please add the following to your config.yaml

logger:
  default: warning
  logs:
    custom_components.aqua_temp: debug

Or use the HA capability in device page: Settings -> Devices & Services -> Aqua Temp -> 3 dots menu -> Enable debug logging When done and would like to extract the log: Settings -> Devices & Services -> Aqua Temp -> 3 dots menu -> Disable debug logging

Please attach also diagnostic details of the integration, available in: Settings -> Devices & Services -> Aqua Temp -> 3 dots menu -> Download diagnostics

Data from mobile app

If mapping for your device are incorrect, please follow the steps below before reporting an issue:

  1. Install on your mobile device packet sniffer (I'm using for Android - NetCapture)
  2. Activate the packet sniffer just for the app
  3. Open the app
  4. Login
  5. Open relevant device
  6. Open menu
  7. Click on Parameter Settings
  8. First cycle, use password for user parameters, code: 022
  9. Take screenshot of each screen (letter)
  10. Repeat steps 8 & 9 with code 066 - factory parameters
  11. Open packet sniffer app and extract requests (and responses) of login, deviceList, getDataByCode

Attach the following details to issue:

  • Mobile App name and version
  • Attach screenshots and logs as zip file or link for download
  • Attach diagnostic details from HA integration

Invalid Token

In case you have referenced to that section, something went wrong with the encryption key, Encryption key should be located in .storage/aqua_temp.config.json file under data.key property, below are the steps to solve that issue.

File not exists or File exists, data.key is not

Please report as issue

File exists, data.key is available

Example:

{
  "version": 1,
  "minor_version": 1,
  "key": "aqua_temp.config.json",
  "data": {
    "key": "ox-qQsAiHb67Kz3ypxY19uU2_YwVcSjvdbaBVHZJQFY="
  }
}

OR

{
  "version": 1,
  "minor_version": 1,
  "key": "aqua_temp.config.json",
  "data": {
    "key": "ox-qQsAiHb67Kz3ypxY19uU2_YwVcSjvdbaBVHZJQFY="
  }
}
  1. Remove the integration
  2. Delete the file
  3. Restart HA
  4. Try to re-add the integration
  5. If still happens - report as issue

File exists, key is available under one of the entry configurations

Example:

{
  "version": 1,
  "minor_version": 1,
  "key": "aqua_temp.config.json",
  "data": {
    "b8fa11c50331d2647b8aa7e37935efeb": {
      "key": "ox-qQsAiHb67Kz3ypxY19uU2_YwVcSjvdbaBVHZJQFY="
    }
  }
}
  1. Move the key to the root of the JSON
  2. Restart HA
  3. Try to re-add the integration
  4. If still happens - follow instructions of section #1 (i.)

Discord