/serilog-sinks-mssqlserver

A Serilog sink that writes events to Microsoft SQL Server

Primary LanguageC#Apache License 2.0Apache-2.0

Serilog.Sinks.MSSqlServer

Build status

A Serilog sink that writes events to Microsoft SQL Server. While a NoSql store allows for more flexibility to store the different kinds of properties, it sometimes is easier to use an already existing MS SQL server. This sink will write the logevent data to a table and can optionally also store the properties inside an Xml column so they can be queried.

Package - Serilog.Sinks.MSSqlServer | Platforms - .NET 4.5

var log = new LoggerConfiguration()
    .WriteTo.MSSqlServer(connectionString: @"Server=...", tableName: "Logs")
    .CreateLogger();

You'll need to create a table like this in your database:

CREATE TABLE [Logs] (

   [Id] int IDENTITY(1,1) NOT NULL,
   [Message] nvarchar(max) NULL,
   [MessageTemplate] nvarchar(max) NULL,
   [Level] nvarchar(128) NULL,
   [TimeStamp] datetimeoffset(7) NOT NULL,  -- use datetime for SQL Server pre-2008
   [Exception] nvarchar(max) NULL,
   [Properties] xml NULL,
   [LogEvent] nvarchar(max) NULL

   CONSTRAINT [PK_Logs] 
     PRIMARY KEY CLUSTERED ([Id] ASC) 
	 WITH (PAD_INDEX = OFF, STATISTICS_NORECOMPUTE = OFF, IGNORE_DUP_KEY = OFF,
	       ALLOW_ROW_LOCKS = ON, ALLOW_PAGE_LOCKS = ON) 
     ON [PRIMARY]

) ON [PRIMARY];

If you don't plan on using one or more columns, you can specify which columns to include in the columnOptions.Store parameter. The Level column should be defined as a TinyInt if the columnOptions.Level.StoreAsEnum is set to true.

NOTE Make sure to set up security in such a way that the sink can write to the log table.

XML configuration

If you are configuring Serilog with the ReadFrom.AppSettings() XML configuration support, you can use:

<add key="serilog:using:MSSqlSever" value="Serilog.Sinks.MSSqlServer" />
<add key="serilog:write-to:MSSqlServer.connectionString" value="Server=..."/>
<add key="serilog:write-to:MSSqlServer.tableName" value="Logs"/>

To use a connection string from the <connectionStrings> element, specify its name as the value of the connection string property.

Writing properties as columns

This feature will still use all of the default columns and provide additional columns for that can be logged to (be sure to create the extra columns via SQL script first). This gives the flexibility to use as many extra columns as needed.

var columnOptions = new ColumnOptions
{
    AdditionalDataColumns = new Collection<DataColumn>
    {
        new DataColumn {DataType = typeof (string), ColumnName = "User"},
        new DataColumn {DataType = typeof (string), ColumnName = "Other"},
    }
};

var log = new LoggerConfiguration()
    .WriteTo.MSSqlServer(@"Server=.\SQLEXPRESS;Database=LogEvents;Trusted_Connection=True;", "Logs", columnOptions: columnOptions)
    .CreateLogger();

The log event properties User and Other will now be placed in the corresponding column upon logging. The property name must match a column name in your table.

In addition, columns can be defined with the name and data type of the column in SQL Server. Columns specified must match database table exactly. DataType is case sensitive, based on SQL type (excluding precision/length).

  <configSections>
    <section name="MSSqlServerSettingsSection"
             type="Serilog.Configuration.MSSqlServerConfigurationSection, Serilog.Sinks.MSSqlServer"/>
  </configSections>
  <MSSqlServerSettingsSection>
    <Columns>
      <add ColumnName="EventType" DataType="int"/>
      <add ColumnName="Release" DataType="varchar"/>
    </Columns>
  </MSSqlServerSettingsSection>      

Auto-create Table

If you set the autoCreateSqlTable option to true, it will create a table for you in the database specified in the connection string. Make sure that the user associated with this connection string has enough rights to make schema changes.

Excluding redundant items from the Properties column

By default the additional properties will still be included in the XML data saved to the Properties column (assuming that is not disabled via the columnOptions.Store parameter). That's consistent with the idea behind structured logging, and makes it easier to convert the log data to another (e.g. NoSQL) storage platform later if desired.

However, if the data is to stay in SQL Server, then the additional properties may not need to be saved in both columns and XML. Use the columnOptions.Properties.ExcludeAdditionalProperties parameter in the sink configuration to exclude the redundant properties from the XML.

Saving the Log Event Data

The log event JSON can be stored to the LogEvent column. This can be enabled with the columnOptions.Store parameter.

Options for serialization of the Properties column

The serialization of the properties column can be controlled by setting values in the in the columnOptions.Properties parameter.

Names of elements can be controlled by the RootElementName, PropertyElementName, ItemElementName, DictionaryElementName, SequenceElementName, StructureElementName and UsePropertyKeyAsElementName options.

The UsePropertyKeyAsElementName option, if set to true, will use the property key as the element name instead of "property" for the name with the key as an attribute.

If OmitDictionaryContainerElement, OmitSequenceContainerElement or OmitStructureContainerElement are set then the "dictionary", "sequence" or "structure" container elements will be omitted and only child elements are included.

If OmitElementIfEmpty is set then if a property is empty, it will not be serialized.