/pvErhard

ERHARD Plunger/Needle Valves (RKV) Sizing coefficients

Primary LanguageROtherNOASSERTION

library(tidyverse)
#> -- Attaching packages --------------------------------------- tidyverse 1.3.1 --
#> v ggplot2 3.3.5     v purrr   0.3.4
#> v tibble  3.1.5     v dplyr   1.0.7
#> v tidyr   1.1.4     v stringr 1.4.0
#> v readr   2.0.2     v forcats 0.5.1
#> -- Conflicts ------------------------------------------ tidyverse_conflicts() --
#> x dplyr::filter() masks stats::filter()
#> x dplyr::lag()    masks stats::lag()
library(scales)
#> 
#> Attaching package: 'scales'
#> The following object is masked from 'package:purrr':
#> 
#>     discard
#> The following object is masked from 'package:readr':
#> 
#>     col_factor

pvErhard

Provide the data necessary to calculate the Erhard RKV valves.

Installation

You can install the development version of pvErhard like so:

remotes::install_github("ratral/pvErhard")

Zeta ζ and flow coefficient Kv**s values of the ERHARD RKS Valves at a fully-open valve

The Kv**s value expresses the amount of flow in a regulating valve at a fully-open valve position and a pressure differential of 1 bar. The Kv**s value is a special case of the Kv**s value, which indicates the flow at a given valve position and a pressure differential of 1 bar.

library(pvErhard)