dbus-shelly-plug-inverter
Integrate Shelly Plug into Victron Energies Venus OS
Purpose
With the scripts in this repo it should be easy possible to install, uninstall, restart a service that connects the Shelly Plug to the VenusOS and GX devices from Victron. Idea is inspired on @vikt0rm project linked below.
Inspiration
This project with the Victron Venus OS, so I took some ideas and approaches from the following projects - many thanks for sharing the knowledge:
How it works
My setup
- 1-Phase installation
- Shelly Plug with latest firmware
- Measuring AC output of Off-Grid Inverter
- Connected to Wifi netowrk "A" with a known IP
- Venus OS on Raspberry PI 3 4GB
- Victron 150/45 Solar Charge Controller
- Victron SmartShunt
- Connected to Wifi netowrk "A"
Details / Process
As mentioned above the script is inspired by @vikt0rm dbus-shelly-1em-pvinverter implementation. So what is the script doing:
- Running as a service
- connecting to DBus of the Venus OS
com.victronenergy.inverter.http_{DeviceInstanceID_from_config}
- After successful DBus connection Shelly Plug is accessed via REST-API - simply the /status is called and a JSON is returned with all details A sample JSON file from Shelly 1PM can be found here
- Serial/MAC is taken from the response as device serial
- Paths are added to the DBus with default value 0 - including some settings like name, etc
- After that a "loop" is started which pulls Shelly Plug data every 750ms from the REST-API and updates the values in the DBus
Thats it 😄
Pictures
Install & Configuration
Get the code
Just grap a copy of the main branche and copy them to a folder under /data/
e.g. /data/dbus-shelly-plug-inverter
.
After that call the install.sh script.
The following script should do everything for you:
wget https://github.com/rsmith0906/dbus-shelly-plug-inverter/archive/refs/heads/main.zip
unzip main.zip "dbus-shelly-plug-inverter-main/*" -d /data
mv /data/dbus-shelly-plug-inverter-main /data/dbus-shelly-plug-inverter
chmod a+x /data/dbus-shelly-plug-inverter/install.sh
/data/dbus-shelly-plug-inverter/install.sh
rm main.zip
Change config.ini
Within the project there is a file /data/dbus-shelly-plug-inverter/config.ini
- just change the values - most important is the deviceinstance, custom name and phase under "DEFAULT" and host, username and password in section "ONPREMISE". More details below:
Section | Config vlaue | Explanation |
---|---|---|
DEFAULT | AccessType | Fixed value 'OnPremise' |
DEFAULT | SignOfLifeLog | Time in minutes how often a status is added to the log-file current.log with log-level INFO |
DEFAULT | Deviceinstance | Unique ID identifying the shelly 1pm in Venus OS |
DEFAULT | CustomName | Name shown in Remote Console (e.g. name of pv inverter) |
DEFAULT | Phase | Valid values L1, L2 or L3: represents the phase where pv inverter is feeding in |
DEFAULT | Position | Valid values 0, 1 or 2: represents where the inverter is connected (0=AC input 1; 1=AC output; 2=AC input 2) |
ONPREMISE | Host | IP or hostname of on-premise Shelly 3EM web-interface |
ONPREMISE | Username | Username for htaccess login - leave blank if no username/password required |
ONPREMISE | Password | Password for htaccess login - leave blank if no username/password required |
Used documentation
- https://github.com/victronenergy/venus/wiki/dbus#pv-inverters DBus paths for Victron namespace
- https://github.com/victronenergy/venus/wiki/dbus-api DBus API from Victron
- https://www.victronenergy.com/live/ccgx:root_access How to get root access on GX device/Venus OS
- https://shelly-api-docs.shelly.cloud/gen1/#shelly1-shelly1pm Shelly API documentation