Potential bug - pause at 100% occurring after "in-pause" time

Closed this issue · 3 comments

Hi there, my AC3 died so haven't been able to test the "winter" season until today when it was finally replaced. I need to pull the new code to my fork, but I believe I have uncovered a bug. To prevent oscillations when at 100% the inverter is paused as I read the code. The inverter is un paused one hour before the end of the charge period. This morning, my inverter did not unpause and the battery charge and discharge power stayed at 0. Looking at the logs, the SOC reached 100% at 6:11 AM. The charge window ended at 7 AM, so the battery had missed the unpause window, I think?

The kit isn’t half buggy! Giv engineer that replaced my AC3 inverter said they were having failure rates approaching 70% on people with firmware 3013 (one of the ones to fix the SoC jumping bug) and therefore trying to keep people on 3012. I was feeling disappointed I hadn’t waited and got the AIO, but the problems there seem to be even worse!

Should work with latest commit.