eFuse tripping when run at lower amperage
Closed this issue · 3 comments
mechatroniks-git commented
When the fan box is run at less than full amperage (not 2.8, but around 2.2), the efuse trips. At this amperage, the fan box will cycle between being on and off.
mmroden commented
Parts are ordered, gonna build those out.
mechatroniks-git commented
Testing/evaluation
- Test trip current
- Test undervoltage
- Test overvoltage
- Test reverse polarity
- Test fuse thru full PWM range at PWM freq, using highest current draw blower
mmroden commented
Resolved by the current papra-pcb.