tetrabiodistributed/papra-pcba

test that protection circuitry actually protects

Closed this issue · 3 comments

Going to also need to put that in the testing docs

Tested on .4 board by shorting the output to the fan, board survived several attempts

Tested v.5 PCB

  1. Shorted BNC while adjusting the fan output
  2. Applied reverse polarity to the battery terminals

In both cases, board suffered no damage and remained fully functional.

closed by #49