tinfever/FU-Dyson-BMS
(Unofficial) Firmware Upgrade for Dyson V6/V7 Vacuum Battery Management System
CNOASSERTION
Issues
- 2
V8 SV10 PCB pics
#47 opened by npaisnel - 0
Snap Programmer + MPLAB IPE is ineffective
#58 opened by BAM5 - 12
Original Firmware Fix
#34 opened by chaddyyyy - 6
Dyson V8 - BMS 180207-01/04 - Battery SV10
#19 opened by accampato - 1
Regarding the max temperature limit of lithium battery charging and discharging
#56 opened by turenabo - 2
Where Google Sheet About Related Thermistor?
#53 opened by KerisKR - 1
Using PIC k150 to programming chip?
#57 opened by qipsys - 5
- 6
Works on Dyson V8 (YH5)
#30 opened by justinmassiot - 1
When the charger is disconnected from mains electricity, the vacuum cleaner will work briefly
#55 opened by turenabo - 8
Dyson V8 Battery 180207 Overcurrent
#12 opened by karatektus - 3
Old Battery BMS (DC35) 17083-22 12
#18 opened by erguro1973 - 0
- 1
How to Compile From MPLAB X IDE To Hex.file?
#52 opened by KerisKR - 2
V6 PCB: 233718 FU-Dyson-BMS compatible?
#51 opened by Boysolder - 2
- 5
Some notes from successful re-programming
#24 opened by NeilMarley - 2
strange red flashes
#31 opened by jnpa007 - 4
12 blue flashes and 70 yellow flashes
#49 opened by Garovich - 1
v6 flashes red light 16 times
#48 opened by TonyJOE598 - 2
Ghost Triggers on V6
#46 opened by SupaCoder - 3
Programming with PICKIT2 successful
#25 opened by ibarrajo - 1
- 1
Dyson SV10 - 10 Red lights
#44 opened by thechosen2k - 2
Can't be fully charged if only check voltage
#43 opened by turenabo - 5
- 6
v6 Low temperature protection
#39 opened by liujixu1984 - 4
How to compile firmware
#40 opened by liujixu1984 - 4
Low-battery cutoff always activates, excessive cell balance indicator flashes despite good cells, v6 188002
#38 opened by liujixu1984 - 1
Possible to flash using a Flipper Zero?
#37 opened by zhast - 6
Bizarre SV03 issue
#36 opened by dickeos - 8
Flashed - was working now not
#35 opened by ShukranPovo - 1
SV03 PCB 188002 V6
#23 opened by chaddyyyy - 18
Dyson V7 - PCB 228499 - Compatible + Tested
#14 opened by NemoLee - 3
DYSON V7 SV11 228499 0103
#33 opened by chaddyyyy - 17
Dyson V10 Battery pack PCB
#11 opened by black-raison-detre - 2
PCB188002, 8 red flashes & 16 red flashes
#32 opened by turenabo - 1
Sv03 BMS PCB
#29 opened by heathenchildde - 14
V6, don't know how to identify the version of the PCB,and don't know whether the battery is locked or not
#21 opened by kanelau - 0
- 0
Problème du Dyson bms
#27 opened by slimlesaurien - 2
When to flash the firmware?
#26 opened by Tharrington86 - 0
SV11 battery dies around 3.6v on SV11
#22 opened by Fixatron - 4
SV10 images if you still need them
#20 opened by Aleksey1406 - 1
The blue LED is always on
#17 opened by vid8266 - 1
Made a tiny bit of progress.
#16 opened by aldoguzman97 - 4
Dyson V7-SV11-PCB228499...maybe...dead
#15 opened by YorkYYY - 1
DYSON V7 COMPLETE SV11 BATTERY
#13 opened by lazmania - 4
Dyson v8 SV10 - PCB 233725-01/04
#10 opened by yarix - 10