OpenVentilator

Welcome to the OpenVentilator project. This is an OpenSource Ventilator / Mechanical Respirator for the Covid-19 Crisis.

This initiative as well as OpenLung was born on the Open Source COVID19 Medical Supplies Facebook Group by the awareness on creating a Ventilator solution for the scarcity plaguing our society world wide. I contacted Jeremias Almada from Argentina who by that time had presented an Ambu solution and a Cad Design. The idea was interseting but needed improvments

Since than we tryied to stablish some development and community standards and changed several times the project

❗❗DISCLAIMER

PROJECT STATUS: validation with health regulatory institutions and compliance with clinical requirements.

⚠️ WE DO NOT YET GUARANTEE THE OPERATION OF THIS MACHINE

Main Goal

Design, Build, Validate and Supply a reliable Ventilation Medical Equipment for people/regions/countries in dificult economical situations. (That's is why we didn't continued putting efforts on the projects being developed by other teams who have a different society and economical reality)

The equipment must have as few industrial parts as possible. If necessary, industrial parts must be easily accessible, even in small towns and villages.

The equipment should be built independent of the main motor or the ventilation tool (AmbuBag, Bellow etc) to increase modularity of the parts and resources

The equipment can be built with as few tools as possible, and even with the use of scrap to facilitate access to materials.

Thechnical features are still being decided, the ventilator has not being validated yet.

Technical & Medical Requirments (MVP)

[x] Adjusting the ventilation volume 200ml ~ 900ml
[x] Ventilation frequency adjustment 10~25/min
[x] Adjusting the proportion between inhalation and exhalation 1/1 ~ 1/6
[x] Inlet air filtration
[x] Inlet air humidification
[x] Filtration of the exhaust air system with anti-contamination sanitary standards

Risk Control

  • PEEP Valve control between 1mm/h20 ~ 40mm/h20
  • Mechanical Volumetric Ventilation Adjustment
  • Contagion reduction by contaminated air
  • Brazil Sanitary Regulations

Success Criteria

Validated Prototype (Looking for partners for testing on Lung Simulators)

Current Status

OpenVentilator OpenVentilator OpenVentilator

Modules

  • Electronic Controller Status Testing
  • Mechanical Motor Status Implementing
  • Ventilator Status: Validation
  • Humidifier Status: Design
  • Filtering status Implementing
  • Peep Valve Status: Adopted - Thanks to ProjectOpenAir
  • Breathing tube Status: Testing

Software Hardware overview

If do you want to help

First, ** CLICK HERE ** to complete the form please, so we can organize everybody

Then join the whatsappgroup and talk with amanda (+55 11 99735-5042 ): https://chat.whatsapp.com/HRMx9xzVdt8Gpmwgm7ZVZ3

Slack Channel for working in progress discussions...

Documentation, Hardware, Design and Code discussions This was depracated to avoid outsiders looking for profit
Check the decissions ALREADY MADE

If I have seen further it is by standing on the shoulders of Giants.

Speciall thanks to:

All our families, wifes and husbands that for the last days have been supporting us on our crazyness.

All the doctors, nurses and paramedics on the field fighting this common enemy