OpenIMU defaule line polarity of data ready signal
Closed this issue · 1 comments
yifanff commented
Please confirm the default line polarity of data ready signal(OpenIMU330BI, OpenIMU330ZI, SPI interface). Currently the data log catch via SPI interface all based on the assumption that: 1. data ready is default enable and cannot be configured. 2. data ready line polarity default is low upon data ready(following 381 usermanual), high upon data is not ready.
yifanff commented
defaule line polarity of data ready signal is low edge actived