For the output result of CVHD , how to obtain the value of global collective variable(cv) η according to the formula?
Closed this issue · 2 comments
Hello! I am new to CVHD. I encounter some difficult problems, may I ask you for advice? (The attachment is the out.colvars.traj file)
The out.colvars.traj file obtained by lammps running the CVHD method through the modified colvars module, the first line of the content is 'step', 'coord', and 'E_hd'. I originally thought that the 'coord' parameter represented the global collective variable(cv) η mentioned in the paper, but I found that its value gradually increased from e-01 to e+02 . What is the explanation of the coord parameter? How does this parameter relate to the global collective variable η mentioned in the paper? (or how to get the η value)
Thank you very much for help!
you can find explanation in example.multibond
colvarsTrajFrequency 10000 # output every 10000 steps
colvarsRestartFrequency 10000
indexFile atoms.ndx # this example reads an index file
colvar {
name coord
width 0.05 # CV width
bondBreakMulti {
group1 {
indexGroup carbon # Group of first bond partners
}
group2 {
indexGroup hydrogen # Group of second bond partners
}
rmin11 1.40 # rmin of 1-1 interaction
rmax11 2.00 # rmax of 1-1 interaction
rcut11 1.80 # rcut of 1-1 interaction
rmin12 1.00 # and so on...
rmax12 1.60
rcut12 1.50
rmin22 0.10 # here, the 2-2 interaction is excluded
rmax22 0.10 # by setting rcut to be very small
rcut22 0.10
waitTime 5000 # t_w, in time steps
power 6 # p
}
}
cvhd {
name hd # Something descriptive (or not)
colvars coord # The CV (ONLY ONE ALLOWED!)
outputEnergy on # Communicate energy to calling program
dynamicBias on # Toggle dynamic/static bias
maxBias 10.0 # Maximal bias in the static case (now not active), in Energy Units
hillWidth 1.0 # Width of Gaussian (see metadynamics in Colvars)
hillWeight 0.25 # Height of Gaussian (see metadynamics in Colvars), in Energy Units
newHillFrequency 1000 # Frequency of Gaussian addition (see metadynamics in Colvars), in # time steps
wellTempered off # Use Well-Tempered Metadynamics (now not active)
biasTemperature 5000 # Well-Tempered Metadynamics bias temperature
}
`
it's CVs of the systems.