/kr_attitude_eskf

Implementation of error-state kalman filter for attitude determination with MARG sensors

Primary LanguageC++OtherNOASSERTION

kr_attitude_eskf

kr_attitude_eskf is an implementation of the Error-State Kalman Filter described in:

  • “Attitude Error Representations for Kalman Filtering” - F. Landis Markley

Version History

  • 0.0.8:
  • Removed the reference calib option, which produced somewhat poor results anyways.
  • Mag calib code now uses either float or double.
  • Removed kr_math, eigen_conversions dependencies.
  • 0.0.7:
    • AttitudeESKF accepts matrices for covariance parameters, instead of assuming diagonal noise.
    • Noise parameters are not provided by rosparam anymore, and are expected to arrive in the incoming messages.
    • Process model treats gyro covariance with the correct units (rad/s)^2 instead of (rad)^2.
    • Magnetic bias/scale/reference vectors are loaded as lists instead of key-value arrays.
    • Magnetometer calibration now uses least squares for initial guess, and LM iteration is robustified with Cauchy weighting.
    • Calibration is triggered by a callable ROS service, instead of from the launch file options.
    • Added support for diagnostic_updater.
    • Renamed adjusted_field topic to corrected_field.
    • Refactored ROS code into a Node class.
    • Removed broadcast_frame option and tf-dependent code.
    • Pose is always published.
  • 0.0.6:
    • Added publish_pose option.
  • 0.0.5:
    • First public release.

Description

This implementation utilizes accelerometer, gyroscope, and (optionally) the magnetometer in order to provide an attitude estimate. Gyroscope biases are estimated online with a moving average filter.

A 4th order Runge Kutta process model is employed, along with a classical EKF update - save for the error-state modifications. Internally, the filter uses a quaternion parameterization of SO(3), thereby avoiding the uglier qualities of euler angles.

Dependencies

The core ESKF code depends on Eigen. The ROS node + magnetometer calibrator depends on kr_math also.

Parameters

The ROS implementation exposes several parameters:

Parameter Definition Default
enable_magnetometer If true, magnetometer readings are included in the state estimation update. false
mag_calib/bias Bias of the magnetometer. [0,0,0]
mag_calib/scale Scale of the magnetometer. [1,1,1]
mag_calib/reference World frame reference vector of the magnetometer. [0,0,0]
process_scale_factor 'Fudge factor' to multiply by incoming gyro covariances. 1
gyro_bias_thresh Threshold of motion below which we may estimate gyro bias. 0.01 rad/s

When using the node, you should remap ~imu and ~field to the appropriate topics. See attitude_eskf.launch for an example.

Topics

The following topics are always published:

Name Description
filtered_imu Filter orientation, covariance, IMU acceleration, and angular velocity (with bias subtracted).
bias Current estimate of gyroscope bias.
status Status of filter. See Status.msg for details.
pose Stamped pose, with translation component zeroed.

If enable_magnetometer is set, the following topics will also be published:

Name Description
corrected_field Magnetic field, with bias and scale estimates applied.

Calibration

This node includes a built-in magnetometer calibration mode. Calibration is started by calling the begin_calibration service. You will observe a log message on rosout indicating that calibration has started. Steps:

  1. Rotate the device about the world z axis 360 degrees.
  2. Rotate the device 90 degrees about the roll/pitch axis, and then again 360 degrees about the world z axis.
  3. You should see the resulting parameters printed on rosout. They will also be saved to rosparam.
  4. After calibration, enable_magnetometer will be set to true and the magnetic field will be included in the estimate.

Important Operating Notes

  • It is assumed that all IMU topics are strictly synchronized.
  • It is assumed that all IMU sensors are physically aligned.
  • The default value of mag_calib/reference is not valid. You must either calibrate the device, or set a known value using a magnetic model (such as IGRF11).

Bug?

Please report issues to the official package maintainer.

Links