sparkfun/OpenScale

Tare always 8388607 weight nan

dawidwekwejt opened this issue · 0 comments

First time I connected C to WHITE, + to RED and - to BLACK. With this I got always 0 weight, so I changed wiring: C to RED, + to WHITE and - to BLACK. After that I had tared scale and calibrate it with 1L botle. In calibration mode I set 1.000000000000. Why no I got nan value?

Current state

Wiring
UL, UR, LL, LR
C -> RED
+ -> WHITE
- -> BLACK

IMG_20201209_145621

Configuration
Serial Load Cell Converter version 1.2
By SparkFun Electronics
No remote sensor found
System Configuration

  1. Tare scale to zero [8388607]
  2. Calibrate scale [0]
  3. Timestamp [On]
  4. Set report rate [2000]
  5. Set baud rate [9600 bps]
  6. Change units of measure [kg]
  7. Decimals [2]
  8. Average amount [4]
  9. Local temp [Off]
    r) Remote temp [Off]
    s) Status LED [Off]
    q) Raw reading [On]
    t) Serial trigger [On]
    c) Trigger character: [48 / '0']
    x) Exit

Log
1006550,nan,kg,8388607,
1008651,nan,kg,8388607,