tetrabiodistributed/project-tetra

Verify new pressure sensor assembly fits inside housing A-TET-001017

Burhan-Q opened this issue · 4 comments

New pressure sensor communication PCB #113 & #114 and wiring harness #67 needs to be checked for clearances in full assembly model.

  • import new pressure sensor assembly A-TET-001017 to Alpha prototype assembly
  • join A-TET-001017 with piping in correct location(s)
  • verify that A-TET-001017 doesn't interfere with other components or creates other assembly or usability issues

Assignments:

Clearance to housing enclosure is 2.637 mm. No other interference observed. Assembly may be rotated to assist with other potential collisions (with any parts currently not added to model).

image

Reviewed 17/08/2020 All changes have been made ready for approval

Housing is now "nice to have"

PCB grew 1 mm, this issue is still open, and not nice-to-have