ethz-asl/hand_eye_calibration

about the trajectory to move the manipulator

Closed this issue · 2 comments

Hi, I am trying to use your tool for hand-eye calibration but do not get a good result. I place a 4 by 5 Aruco board on the desk and move the manipulator around the Aruco board to create my own csv files. But when I run the code to calibrate the camera, it throw the following warning:
"The singular values of this solution are bad. Either the smallest two are too big or the first 6 are too small! "
And the result of the calibration is very poor. The resulting transformation matrix is totally different from the one I get using Tsai's method.

Is that because the trajectory I choose for the manipulator is not good enough, or I don't have enough data in the csv files? The trajectory is chosen randomly, and I have 40 poses in each csv file.

1869725925

Made a big mistake. I used the the pose of the aruco calibration board instead of the camera pose in reference to the world frame.

hello ,,i also got this problem, but , i use the camera_pose indeed,,here is my aligned_data

camera_aligned.txt
vicon_aligned.txt

I need to use this package to calibrate extrinsic param between the realsense camera and the vicon markers(rigidbody) stick on the camera.
data describtion:
vicon_aligned: --poses_B_H_csv_file
camera_aligned: --poses_W_E_csv_file (localize the camera with one ARUCO marker)

After the calibration routings ,I got this
The singular values of this solution are bad. Either the smallest two are too big or the first 6 are too small! singular values: [ 5.61685252 5.00851638 4.4412948 4.10509097 3.46701731 3.09330403
1.82952841 1.55362262]