One console with two separate connected fans
Closed this issue · 2 comments
marxbenjamin commented
Hello,
first of all respect and thanks for the guide! It was fun building it.
I connected two fans (one for in, one for out) to different pins. - I know I could have just soldered them together, but I didn't want to. - I can now control both separately and also get all sensor values output separately.
But I would like to specify only one target temperature value via the console and this should be given to both output IDs.
Is this possible? As far as I understand, I would have to specify both IDs of the "cool_output" here in the code. But I can't find the syntax for it.
climate:
- platform: pid
name: "Console Fan Thermostat Out"
id: console_thermostat_out
sensor: console_fan_temperature
# It is summer right now, so 30c is a decent target.
default_target_temperature: 30°C
cool_output: console_fan_speed
DunklesKaltesNichts commented
this is not possible, you can only specify one output.
this is my solution:
substitutions:
nodename: fancontrol
- platform: template
id: pwm_merge
type: float
write_action:
- output.set_level:
id: ${nodename}_pwm_inward
level: !lambda return state;
- output.set_level:
id: ${nodename}_pwm_outward
level: !lambda return state;
# PWM Fan inward
- platform: ledc
pin: GPIO26
id: ${nodename}_pwm_inward
frequency: 25khz
# PWM fan outward
- platform: ledc
pin: GPIO25
id: ${nodename}_pwm_outward
frequency: 25khz
cool_output: pwm_merge
marxbenjamin commented
Thanks very much! It works as expected! :)